2,042,423Injury reports 130,778Establishments Most recent incident 2025-12-31
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Injury Report: SUPER RADIATOR COILS

Injury · Days away from work

On , an injury at SUPER RADIATOR COILS in Richmond, VA 23236 resulted in days away from work. Employee was brazer in exchangers, heat, manufacturing.

Establishment
SUPER RADIATOR COILS
Parent company
SUPER RADIATOR COILS
Street
451 Southlake Blvd
City
Richmond
State
VA
ZIP
23236
On-site location
Brazing Department
Outcome
Days away from work (code 2)
Type
Injury (code 1)
Days away from work
6

Employee was brazing a coil

While brazing a piece of braze material popped off and landed on her chest

injury

braze material

Burn to Chest wall

Job description
Brazer
SOC code
9999 — Uncoded
NAICS code
332410 — Exchangers, heat, manufacturing
NAICS vintage
2022
Avg employees
344
Total hours worked
698758
EIN
411533780
Establishment ID
1062878
Employer case #
2023082
Date of incident
Shift started
6:00:00.000
Time of incident
10:00:00.000
Submitted
26DEC24:20:18:00

Data from OSHA ITA Form 300/301 electronic submissions, filing year unspecified. ITA Case Detail records are establishment-reported submissions, not OSHA inspections — no per-record IMIS deep link exists.