OSHA Inspection: TOLOCKO BUILDERS

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of TOLOCKO BUILDERS in 13725 W. CAPITOL DRIVE, BROOKFIELD, WI 53005 (NAICS 000000). OSHA activity number 100149368.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Tolocko Builders for free Get an email when a new federal OSHA severe-injury report for Tolocko Builders is published. One employer, no account, unsubscribe in one click.
Establishment
TOLOCKO BUILDERS
Site address
13725 W. CAPITOL DRIVE
City
BROOKFIELD
State
WI
ZIP
53005
Mailing
211 S. MAIN, THIENSVILLE, WI 53092
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Data loaded
NAICS code
000000
SIC code (legacy)
1542
Employees
2
Ownership type
A
Industry flags
Construction safety.

1 citation on file for this inspection.

5(a)(1)

Serious 1 instance 2 exposed
Issued
Sep 30, 1986
Abate by
Oct 3, 1986
Penalty
Initial $720 · Current $450 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
a) On August 20, 1986 employee(s) were exposed to a potential fall
and/or crushing hazard with was caused by inadequate bracing and
support of roof trusses.
A feasible method of abatement includes, but is not limited to: adequate
bracing of continuous lumber (no less than 2" x 4" nominal) running
parallal to the ridge line and spaced 8" to 10" apart in the top chord
and bottom chord planes. These are to be supplemented with diagonal
bracing (no less than 2" x 4" nominal) spaced no more than twenty feet
apart in the top and bottom chord planes and among the web members.
These are to be secured with 16d nails.