Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: KEMIRA, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of KEMIRA, INC. in DEPTFORD TRACT, SAVANNAH, GA 31401 (NAICS 000000). OSHA activity number 100356096.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Kemira, INC. — free Get an email when a new federal OSHA severe-injury report for Kemira, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
KEMIRA, INC.
Site address
DEPTFORD TRACT
City
SAVANNAH
State
GA
ZIP
31401
Mailing
P. O. BOX 368, SAVANNAH, GA 31402
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Data loaded
NAICS code
000000
SIC code (legacy)
2816
Employees
651
Ownership type
A
Industry flags
Manufacturing safety.

3 citations on file for this inspection.

5(a)(1)

Serious 1 instance 60 exposed
Issued
Dec 4, 1985
Abate by
May 6, 1986
Penalty
Initial $300 · Current $300
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not furnish employment and a place of employment on or
about 10/31/85 which were free from recognized hazards that were free
from recognized hazards that were causing or likely to cause death or
serious physical harm to employees in that employees were exposed to the
hazard of chlorine gas being released into the working environment of
the Chloride Plant in the event of an electrical power failure when:
a) The back-up steam turbine for the scrubber system was not kept
operational; and,
b) The manual dump/vent valve was too remote for rapid access to open
it.
Among other methods, two feasible and acceptable methods to correct this
hazard is (a) Provide a compressed gas accumulator or reliable source of
compressed gas to run the turbine and (b) Provide an automatic dump/vent
valve that would fall open and relieve pressure in the system to the
scrubber.
Recent events (2)
  • — P (S) $300.00
  • — Z (S) $300.00

1910.165 D01

Serious 1 instance 150 exposed
Issued
Dec 4, 1985
Abate by
Jul 6, 1986
Penalty
Initial $240 · Current $240
Recent events (2)
  • — P (S) $240.00
  • — Z (S) $240.00

1910.307 B

Serious 1 instance 3 exposed
Issued
Dec 4, 1985
Abate by
Jan 6, 1986
Penalty
Initial $180 · Current $180

View Kemira, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 100356096.