NEWARK, NJ —
OSHA Inspection: SUN CHEMICAL CORPORATION/PIGMENTS DIVISION
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of SUN CHEMICAL CORPORATION/PIGMENTS DIVISION in 185 FOUNDRY STREET, NEWARK, NJ 07105 (NAICS 000000). OSHA activity number 100513522.
Where did this inspection happen?
- Establishment
- SUN CHEMICAL CORPORATION/PIGMENTS DIVISION
- Site address
- 185 FOUNDRY STREET
- City
- NEWARK
- State
- NJ
- ZIP
- 07105
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 2816
- Employees
- 17
- Ownership type
- A
- Industry flags
- Manufacturing health.
Citations
5 citations on file for this inspection.
5(a)(1)
- Issued
- Oct 27, 1988
- Abate by
- Jan 30, 1989
- Penalty
- Initial $240 · Current $145 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: a) Reactors Bldg. - Chemical burns or death from potential chemical explosion in the large reflux reactor. The reactor is used in the manufacture of organic pigments and is heated up to 120 degrees celsius with steam at 60 psi maximum. Provisions were not made to shut down the heat automatically if excess temperature was sensed in the reactor. All controls are manual. There are no sensors in the reflux columns. Methanol, poliphosphoric acid and glacial acetic acid are used in the process. Feasible and acceptable methods to correct this hazard are - 1) Install automatic temperature control. The addition of audible high temperature and pressure alarms is desirable. 2) Install redundant interlocks between cooling water and heat input which would allow the heat to shut off if the supply fails. Violation observed on or about 7/8/88.
Recent events (2)
- — I (S) $145.00
- — Z (S) $240.00
1910.20 D01 II
- Issued
- Sep 2, 1988
- Abate by
- Sep 19, 1988
1910.134 B01
- Issued
- Sep 2, 1988
- Abate by
- Sep 19, 1988
1910.134 B05
- Issued
- Sep 2, 1988
- Abate by
- Sep 6, 1988
1910.1200 F04 I
- Issued
- Sep 2, 1988
- Abate by
- Sep 19, 1988
More inspections in this industry (NAICS 000000)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 100513522.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.