LONGMONT, CO ·
OSHA Inspection: CIRCUIT WEST INC.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of CIRCUIT WEST INC. in 1121 COLORADO AVENUE, LONGMONT, CO 80501 (NAICS 000000). OSHA activity number 100562123.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CIRCUIT WEST INC.
- Site address
- 1121 COLORADO AVENUE
- City
- LONGMONT
- State
- CO
- ZIP
- 80501
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 3672
- Employees
- 9
- Ownership type
- A
- Industry flags
- Manufacturing health.
Citations
9 citations on file for this inspection.
5(a)(1)
- Issued
- Mar 27, 1992
- Abate by
- Apr 30, 1992
- Penalty
- Initial $1,500 · Current $600 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to asphyxiation and/or chemical poisoning from the hazards of oxygen deficiency and/or dangerous accumulations of toxic substances during confined space entry: (a) On 1/23/92 an employee entered a pipe valve vault in the Plating Room to release treated wastewater from a holding sump into the city sewer system. The employer's confined space entry program was deficient in that: 1. A confined space entry permit system was not in place. 2. The employee was not trained in the hazards associated with entering confined spaces or with the methods that the employee could use to minimize these hazards. 3. Atmospheric testing for oxygen deficiency, flammable gas and toxic air contaminants was not conducted prior to entering the confined space. 4. Mechanical ventilation was not used to purge the con- fined space of dangerous atmospheric contaminants and to maintain a supply of fresh air. 5. An emergency response rescue program was not developed or implemented. Among other methods, two feasible and acceptable methods to abate these hazards area: a. Devise and install and device to remotely operate the treated-water release valve to preclude the necess- ity of employees entering the manhole. b. If at any time it is necessary that employees enter the manhole, or any other confined space, developed and implement a confined space entry program which meets the criteria of Safety Requirements For Confined Spaces, American national Standard Institute (ANSI Z117.1 - 1989).
Recent events (2)
- · I (S) $600.00
- · Z (S) $1500.00
5(a)(1)
- Issued
- Mar 27, 1992
- Abate by
- Apr 30, 1992
- Penalty
- Initial $750 · Current $300 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to incompatible chemical storage which could lead to fire, explosion or the generation of toxic gas: (a) In the Chemical Storage Area three 100lb cans of 42 nitric acid, three 55 gal. drums of 50hydrogen peroxide, and four 55 gal. drums of 50sodium hydroxide were stored within close proximity to each other. 1. Accidental mixture of nitric acid with hydrogen peroxide can result in a violent reaction. 2. Accidental mixture of nitric acid with sodium hydroxide can result in a violent reaction. 3. Accidental mixture of hydrogen peroxide with sodium hydroxide can result in a violent reaction. Among other methods, one feasible and acceptable method to abate these hazards are to store these incompatible chem- icals in separate physical locations or to store the highly reactive oxidizers (nitric acid and hydrogen peroxide) each in separate approved chemical storage cabinets.
Recent events (2)
- · I (S) $300.00
- · Z (S) $750.00
1910.36 B04
- Issued
- Mar 27, 1992
- Abate by
- Apr 6, 1992
- Penalty
- Initial $600 · Current $240 Reduced
Recent events (2)
- · I (S) $240.00
- · Z (S) $600.00
1910.120 Q01
- Issued
- Mar 27, 1992
- Abate by
- May 21, 1992
Recent events (2)
- · I (S)
- · Z (S)
1910.1200 E01
- Issued
- Mar 27, 1992
- Abate by
- May 21, 1992
- Penalty
- Initial $600 · Current $240 Reduced
Recent events (2)
- · I (S) $240.00
- · Z (S) $600.00
1910.1200 F05 I
- Issued
- Mar 27, 1992
- Abate by
- Apr 30, 1992
Recent events (2)
- · I (S)
- · Z (S)
1910.1200 F05 II
- Issued
- Mar 27, 1992
- Abate by
- Apr 30, 1992
Recent events (2)
- · I (S)
- · Z (S)
1903.2 A01
- Issued
- Mar 27, 1992
- Abate by
- Apr 30, 1992
- Penalty
- Initial $300 · Current $120 Reduced
Recent events (2)
- · I (O) $120.00
- · Z (O) $300.00
1910.1048 D01 I
- Issued
- Mar 27, 1992
- Abate by
- Mar 31, 1992
Recent events (2)
- · I (O)
- · Z (O)
More inspections in this industry (NAICS 000000)