Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: AIRCO CARBON DIV. OF BOC INC.

Accident-driven inspection · Safety discipline

On , OSHA opened an accident-driven safety inspection of AIRCO CARBON DIV. OF BOC INC. in 4861 PACKARD ROAD, NIAGARA FALLS, NY 14302 (NAICS 000000). OSHA activity number 100669019.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Airco Carbon DIV. of BOC INC. for free Get an email when a new federal OSHA severe-injury report for Airco Carbon DIV. of BOC INC. is published. One employer, no account, unsubscribe in one click.
Site address
4861 PACKARD ROAD
City
NIAGARA FALLS
State
NY
ZIP
14302
Inspection type
Accident-driven (A)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Data loaded
NAICS code
000000
SIC code (legacy)
3624
Employees
540
Ownership type
A
Industry flags
Manufacturing safety.

3 citations on file for this inspection.

5(a)(1)

Serious 1 instance 2 exposed
Issued
Dec 11, 1987
Abate by
Dec 30, 1987
Penalty
Initial $720 · Current $360 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
a) The hazard of electrical shock which could result in death due to the
accidental energizing of bare, live 240-volt electrical wires which
were exposed to contact by employees who were rebuilding the gear box
on the P & H 5-ton bridge crane in Plant 2, on or about 9/11/87.
One feasible and acceptable abatement method among others, to correct
this hazard, is to establish and enforce an adequate plant lockout
procedure such as that stipulated by ANSI B30.17-1985, Section 17-2.3.2
(2) and (3), American National Standard Overhead and Gantry Cranes, and
by ANSI Z244.1-1982, Section 4 and 5, American National Standard of
Minimum Safety Requirements for Lockout/Tagout of Energy Sources for
Personnel Protection.
Essential elements of the lockout procedure would include:
1) Open and lock out the main power disconnect for the machine and bleed
off any residual energy;
2) Provide each potentially exposed employee working in the area with
separate lock and key to be placed on the lockout means;
3) Establish a written lockout policy, including procedures to be
followed and training for all affected employees, both maintenance
and operational crews;
4) Periodically evaluate the program and strictly enforce all of its
provisions.
Recent events (2)
  • · I (S) $360.00
  • · Z (S) $720.00

1910.23 A07

Serious 9 instances 10 exposed
Issued
Nov 24, 1987
Abate by
Apr 29, 1988
Penalty
Initial $720 · Current $360 Reduced
Recent events (2)
  • · I (S) $360.00
  • · Z (S) $720.00

1910.24 E

Other-than-serious 1 instance 3 exposed
Issued
Nov 24, 1987
Abate by
Nov 27, 1987

View Airco Carbon DIV. of BOC INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 100669019.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.