Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: NORTHEAST UTILITIES

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of NORTHEAST UTILITIES in SHELDON AND PROSPECT STREETS, HARTFORD, CT 06103 (NAICS 000000). OSHA activity number 100770700.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Northeast Utilities — free Get an email when a new federal OSHA severe-injury report for Northeast Utilities is published. One employer, no account, unsubscribe in one click.
Establishment
NORTHEAST UTILITIES
Site address
SHELDON AND PROSPECT STREETS
City
HARTFORD
State
CT
ZIP
06103
Mailing
107 SELDON STREET, BERLIN, CT 06037
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Data loaded
NAICS code
000000
SIC code (legacy)
1731
Employees
391
Ownership type
A
Industry flags
Construction safety.

1 citation on file for this inspection.

5(a)(1)

Serious Gravity 08 1 instance 2 exposed
Issued
Jul 20, 1989
Abate by
Jul 26, 1989
Penalty
Initial $800 · Current $400 Reduced
Section 5(a)(1) of the Occupational safety and Health Act of 1970:  The
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to
the hazards of electrical shocks and/or electrical burns:
JOBSITE:  A DROPLIGHT WAS USED FOR TEMPORARY LIGHTING IN THE MANHOLE.
THE END OF THE CORD FOR THE LIGHT HAD ALLIGATOR CLIPS CONNECTED TO THE
WIRES.  THE "HOT" WIRE WAS ATTACHED TO A NAIL WHICH HAD BEEN HAMMERED
INTO ONE OF THE SECONDARY FEEDER CONDUCTORS.  THE NEUTRAL AND GROUND
WIRES WERE ATTACHED TO A SAFE GROUND ALONG THE WALL OF THE MANHOLE.
AMONG OTHER METHODS, ONE FEASIBLE AND ACCEPTABLE ABATEMENT METHOD TO
CORRECT THIS HAZARD IS OBTAIN TEMPORARY POWER FOR LIGHTING FROM THE
GENERATOR ON THE SERVICE TRUCK.
Recent events (2)
  • — I (S) $400.00
  • — Z (S) $800.00

View Northeast Utilities's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 100770700.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.