Plymouth, MA ·
OSHA Inspection: BOSTON INSULATED WIRE & CABLE
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of BOSTON INSULATED WIRE & CABLE in COURT ST CORDAGE PARK, Plymouth, MA 02360 (NAICS 000000). OSHA activity number 10093854.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BOSTON INSULATED WIRE & CABLE
- Site address
- COURT ST CORDAGE PARK
- City
- Plymouth
- State
- MA
- ZIP
- 02360
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 3357
- Employees
- 185
- Industry flags
- Manufacturing safety.
Citations
10 citations on file for this inspection.
1910.212 A01
- Issued
- Jun 26, 1981
- Abate by
- Nov 30, 1981
- Penalty
- Initial $400 · Current $200 Reduced
Recent events (3)
- · Z (S) $400.00
- · P (S) $200.00
- · I (S) $200.00
1910.219 F03
- Issued
- Jun 26, 1981
- Abate by
- Aug 17, 1981
- Penalty
- Initial $400 · Current $200 Reduced
Recent events (2)
- · Z (S) $400.00
- · I (S) $200.00
1910.219 D01
- Issued
- Jun 26, 1981
- Abate by
- Jun 29, 1981
- Penalty
- Initial $80 · Current $40 Reduced
Recent events (2)
- · Z (O) $80.00
- · I (O) $40.00
1910.219 F01
- Issued
- Jun 26, 1981
- Abate by
- Aug 17, 1981
- Penalty
- Initial $80 · Current $40 Reduced
Recent events (2)
- · Z (O) $80.00
- · I (O) $40.00
1910.106 E06 I
- Issued
- Jun 10, 1981
- Abate by
- Jun 13, 1981
1910.212 A01
- Issued
- Jun 10, 1981
- Abate by
- Jun 29, 1981
1910.212 A02
- Issued
- Jun 10, 1981
- Abate by
- Jun 22, 1981
1910.212 A03 II
- Issued
- Jun 10, 1981
- Abate by
- Jun 13, 1981
1910.215 B09
- Issued
- Jun 10, 1981
- Abate by
- Jun 13, 1981
1910.304 F05 VC
- Issued
- Jun 10, 1981
- Abate by
- Jun 13, 1981
More inspections at Boston Insulated Wire & Cable
View Boston Insulated Wire & Cable's full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in MA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 10093854.