DUBUQUE, IA —
OSHA Inspection: AMERICAN BOAT COMPANY
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of AMERICAN BOAT COMPANY in MISSISSIPPI RIVER MILE MARKER 580, DUBUQUE, IA 52001 (NAICS 000000). OSHA activity number 101383180.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AMERICAN BOAT COMPANY
- Site address
- MISSISSIPPI RIVER MILE MARKER 580
- City
- DUBUQUE
- State
- IA
- ZIP
- 52001
- Mailing
- P.O. BOX 8100, ALTON, IL 62002
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 4449
- Employees
- 10
- Ownership type
- A
Citations
21 citations on file for this inspection.
5(a)(1)
- Issued
- Jul 2, 1992
- Abate by
- Jun 1, 1993
- Penalty
- Initial $3,500 · Current $1,300 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to electrical shock and electrical burns where employees could easily damage or contact energized electrical wires, joints, connections, splices or lugs carrying 110 and 220 volt AC to include but not limited to the following locations and equipment: I. The employees were exposed to contact with live electrical wires and lugs carrying 110 and 220 volt AC associated with panelboards in cabinest, cutout boxes, pull boxes and junction boxes or enclosures: (a) main air compressor circuit breaker in the air compressor room. (b) back-up air compressor circuit breaker in the air compressor room. (c) motor controller in the air compressor room. (d) sanitation pump motor circuit breaker in the air compressor room. (e) fuel pump motor circuit breaker in the fuel pump room. (f) bilge pump motor circuit breaker in the fuel pump room. (g) motor controller for fuel pumps in the fuel pump room. (h) cooling water pump motor circuit breaker in the fuel pump room. (i) junction box in the entry hall to fresh water room. (j) junction box on wall next to refrigeration unit. (k) junction box on the refrigeration unit motor. (l) junction box for the old indicator lights on the upper engine room deck. (m) outlet box on the aft deck. (n) outlet box for aft deck light next to engine room door. (o) outlet box in the hallway from the engine room to the bow storage area. (p) outlet box near the work bench. (q) outlet box near the starboard door on the upper engine room deck. II. Employees were exposed to contact with energized 110 volt AC electrical wiring associated with switchboard: (a) main control switchboard on upper engine room deck. III. Employees were exposed to contact with live 110 volt AC in flexible cords which could be easily damaged where run as a substitute as permanent wiring; through holes in the walls, ceilings, or floors; or through doorways, windows, or similar openings: (a) where flexible cord on aft deck was run into engine room through the aft engine room door. (b) where flexible cord on the aft deck was used on the aft deck to supply power to receptacle outlets and aaft running lights. (c) where flexible cords were used in the hallway between engine room and the bow storage area. (d) where flexible cords were run through holes in the aft engine room wall from aft deck. (e) where flexible power supply cord for the welding machine is run through the main electrical panel door. IV. Employees were exposed to contact with live 110 volt AC in flexible cords which were not used in continuous lengths without splice or tap: (a) flexible cord on the aft deck. V. Employees were exposed to contact with live 110 volt AC in flexible cords or the devices they were connected to where no strain relief is provided and a direct pull is being applied to the joints and terminations: (a) flexible cord connected to outlet box on aft deck. (b) flexible cord of the welding machine connected to circuit breaker termination screws in the main panel box on upper engine room deck. (c) flexible cord connected to lampholder on aft deck and in hallway from engine room to bow storage area. VI. Employees were exposed to contact with noncurrent carrying metal parts of cord and plug connected equipment when plugged into outlet receptacles would be connected in reverse polarity: (a) receptacle outlet near work bench on upper engine room deck. (b) receptacle outlet near starboard engine room door. AMONG OTHER METHODS, ONE FEASIBLE AND ACCEPTABLE ABATEMENT METHOD TO CORRECT THIS HAZARD IS: I. Provide and install manufacturers covers for circuit breaker panelboxes, motor switches, outlet and junction boxes, and fixtures including, but not limited to the following: (a) main air compressor circuit breaker in the air compressor room. (b) back-up air compressor circuit breaker in the air compressor room. (c) motor controller in the air compressor room. (d) sanitation pump motor circuit breaker in the air compressor room. (e) fuel pump motor circuit breaker in the fuel pump room. (f) bilge pump motor circuit breaker in the fuel pump room. (g) motor controller for fuel pumps in the fuel pump room. (h) cooling water pump motor circuit breaker in the fuel pump room. (i) junction box in the entry hall to fresh water room. (j) junction box on wall next to refrigeration unit. (k) junction box on the refrigeration unit motor. (l) junction box for the old indicator lights on the upper engine room deck. (m) outlet box on the aft deck. (n) outlet box for aft deck light next to enginer room door. (o) outlet box in the hallway from the engine room to the bow storage area. (p) outlet box near the work bench. (q) outlet box near the starboard door on the upper engine room deck. II. Assure switchboard with energized electrical wiring and parts are only accessible to qualified persons: (a) main control switchboard on upper engine room deck. III. Install electrical wiring per boat and equipment manufacturers specifications in a permanent manner: (a) where flexible cord on aft deck was run into engine room through the aft engine room door. (b) where flexible cord on the aft deck was used on the aft deck to supply power to receptacle outlets and aft running lights. (c) where flexible cords were used in the hallway between engine room and the bow storage area. IV. Assure equipment used in wet and damp locations is approved for that application, including but not limited to the following: (a) receptacle outlet near work bench on upper engine room deck. V. Where flexible cords are connected to devices and fittings assure that strain relief is provided which will prevent pull from being directly transmitted to the joints or terminal screws: (a) flexible cord connected to outlet box on aft deck. (b) flexible cord of the welding machine connected to circuit breaker termination screws in the main panel box on upper engine room deck. (c) flexible cord connected to lampholder on aft deck and in hallway from engine room to bow storage area. VI. Assure grounded conductors are installed with the correct polarity, including but not limited to the following: (a) receptacle outlet near work bench on upper engine room deck. (b) receptacle outlet near starboard engine room door.
Recent events (2)
- — R (S) $1300.00
- — Z (S) $3500.00
1910.23 C01
- Issued
- Jul 2, 1992
- Abate by
- Jun 1, 1993
- Penalty
- Initial $1,400 · Current $610 Reduced
Recent events (2)
- — R (S) $610.00
- — Z (S) $1400.00
1910.106 E02 IVD
- Issued
- Jul 2, 1992
- Abate by
- Jun 1, 1993
- Penalty
- Initial $1,400 · Current $610 Reduced
Recent events (2)
- — R (S) $610.00
- — Z (S) $1400.00
1910.106 E09 I
- Issued
- Jul 2, 1992
- Abate by
- Jun 1, 1993
- Penalty
- Initial $2,450
Recent events (2)
- — R (S)
- — Z (S) $2450.00
1910.147 C01
- Issued
- Jul 2, 1992
- Abate by
- Jun 1, 1993
- Penalty
- Initial $3,500
Recent events (2)
- — R (S)
- — Z (S) $3500.00
1910.151 B
- Issued
- Jul 2, 1992
- Abate by
- Jun 1, 1993
- Penalty
- Initial $1,750 · Current $700 Reduced
Recent events (2)
- — R (S) $700.00
- — Z (S) $1750.00
1910.151 B
- Issued
- Jul 2, 1992
- Abate by
- Jul 28, 1992
Recent events (2)
- — R (S)
- — Z (S)
1910.157 G01
- Issued
- Jul 2, 1992
- Abate by
- Jun 1, 1993
- Penalty
- Initial $3,500 · Current $1,300 Reduced
Recent events (2)
- — R (S) $1300.00
- — Z (S) $3500.00
1910.219 B01
- Issued
- Jul 2, 1992
- Abate by
- Jun 1, 1993
- Penalty
- Initial $1,750 · Current $650 Reduced
Recent events (2)
- — R (S) $650.00
- — Z (S) $1750.00
1910.219 C02 I
- Issued
- Jul 2, 1992
- Abate by
- Jun 1, 1993
- Penalty
- Initial $2,450 · Current $1,000 Reduced
Recent events (2)
- — R (S) $1000.00
- — Z (S) $2450.00
1910.219 D01
- Issued
- Jul 2, 1992
- Abate by
- Jun 1, 1993
- Penalty
- Initial $1,750 · Current $700 Reduced
Recent events (2)
- — R (S) $700.00
- — Z (S) $1750.00
1910.332 B01
- Issued
- Jul 2, 1992
- Abate by
- Jun 1, 1993
- Penalty
- Initial $3,500 · Current $1,300 Reduced
Recent events (2)
- — R (S) $1300.00
- — Z (S) $3500.00
1910.333 A
- Issued
- Jul 2, 1992
- Abate by
- Jun 1, 1993
- Penalty
- Initial $3,500
Recent events (2)
- — R (S)
- — Z (S) $3500.00
1910.1200 E01
- Issued
- Jul 2, 1992
- Abate by
- Jun 1, 1993
- Penalty
- Initial $1,400 · Current $610 Reduced
Recent events (2)
- — R (S) $610.00
- — Z (S) $1400.00
1910.1200 G01
- Issued
- Jul 2, 1992
- Abate by
- Jun 1, 1993
- Penalty
- Initial $1,400 · Current $610 Reduced
Recent events (2)
- — R (S) $610.00
- — Z (S) $1400.00
1910.1200 H
- Issued
- Jul 2, 1992
- Abate by
- Jun 1, 1993
- Penalty
- Initial $1,400 · Current $610 Reduced
Recent events (2)
- — R (S) $610.00
- — Z (S) $1400.00
1910.20 D01 II
- Issued
- Jul 2, 1992
- Abate by
- Jun 1, 1993
Recent events (2)
- — R (O)
- — Z (O)
1910.20 G01
- Issued
- Jul 2, 1992
- Abate by
- Jun 1, 1993
Recent events (2)
- — R (O)
- — Z (O)
1910.20 G02
- Issued
- Jul 2, 1992
- Abate by
- Jun 1, 1993
Recent events (2)
- — R (O)
- — Z (O)
1910.219 E03 I
- Issued
- Jul 2, 1992
- Abate by
- Jun 1, 1993
Recent events (2)
- — R (O)
- — Z (O)
1910.1200 F05 II
- Issued
- Jul 2, 1992
- Abate by
- Jun 1, 1993
Recent events (2)
- — R (O)
- — Z (O)
More inspections at American Boat Company
View American Boat Company's full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in IA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 101383180.