WAVERLY, NY —
OSHA Inspection: MATCO ELECTRIC, INC.
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of MATCO ELECTRIC, INC. in BEST WESTERN, WAVERLY, NY 14882 (NAICS 000000). OSHA activity number 101549608.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MATCO ELECTRIC, INC.
- Site address
- BEST WESTERN
- City
- WAVERLY
- State
- NY
- ZIP
- 14882
- Mailing
- 320 N. JENSEN ROAD, VESTAL, NY 13850
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Y
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 1731
- Employees
- 39
- Ownership type
- A
- Industry flags
- Construction safety.
Citations
2 citations on file for this inspection.
5(a)(1)
- Issued
- Jun 24, 1994
- Abate by
- Jun 29, 1994
- Penalty
- Initial $975 · Current $488 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: a)ELEVATION 429 LIMESTONE PREP. AREA, EMPLOYEES WERE OPERATING A CORD CONNECTED POWER DRIVE, RIGID MODEL 535 (SERIAL #327480) PIPE THREAD MACHINE WITHOUT THE USE OF A MOMENTARY CONTACT DEVICE TO CONTROL POWER INPUT TO THE MACHINE AS REQUIRED BY ANSI B208.1-1982, SAFETY REQUIREMENTS FOR PIPE TOOLS, CORD CONNECTED, SECTION 4.4. METHOD OF ABATEMENT: Momentary foot switch, Foot switch shall be guarded to prevent unintended operation. Refer to 29CFR 1910.217(b)(4)(i,ii,iii,iv). HAZARD: Employees exposed to the hazard of rotating parts. Employees may become injured if clothing were to become entangled in the rotating parts of the Rigid model #535 cord connected pipe threading machine. HAZARD RECOGNITION: American National Standards Institute, ANSI 208.11982, for tools-cord connected portable pipe threading machines and portable power drives-safety requirements, section 4.4 require "A momentary contact device shall be used to control the power input to the cord connected portable pipe threading machine or power drive. If a foot switch is used it shall be guarded." The employer John Augustine, stated that a momentary foot switch could be provided for the pipe thread machine. SEE ATTACHED ANSI B208.1-1982 LIKELIHOOD OF SERIOUS PHYSICAL HARM: Documented incidents have shown that when clothing becomes entangled with the rotating parts of the cord connected pipe threading machines, the high torque produces serious physical injuries including fractured ribs and difficulty in breathing. Employee entangled in the machine may not be able to reach the on/off switch prolonged self rescuer attempts and increasing the serious nature of the injuries. SEE ATTACHED ELECTRICAL CONSTRUCTION AND MAINTENANCE, OCT. 1988 ABATEMENT METHOD: Momentary foot switch. This foot switch shall be designed in the manner as a "dead man control" so that when pressure is released the machine stops operation. The foot switch shall be guarded in a manner so to protect from unintended operation by accidentally stepping on the pedal orfalling/moving objects contacting the pedal. The pad of the foot switch should be non slip surface. "A search has been made of the 29 CFR Standards and no standard applies to the cited condition. Refer to July 25, 1989, Region II memorandum from Acting ARA Technical Support, Subject: Portable Power Drive Pipe Threading Machine."
Recent events (2)
- — I (S) $487.50
- — Z (S) $975.00
1926.432 A01 I
- Issued
- Jun 24, 1994
- Abate by
- Jun 29, 1994
Recent events (2)
- — I (O)
- — Z (O)
More inspections at Matco Electric, INC.
View Matco Electric, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 101549608.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.