Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,193,745Inspections Most recent open 2026-08-06 Last loaded 2026-08-10

OSHA Inspection: OTIS ELEVATOR COMPANY

Accident-driven inspection · Safety discipline

On , OSHA opened an accident-driven safety inspection of OTIS ELEVATOR COMPANY in 11800 SW 147TH AVE., MIAMI, FL 33169 (NAICS 000000). OSHA activity number 101552255.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Otis Elevator Company for free Get an email when a new federal OSHA severe-injury report for Otis Elevator Company is published. One employer, no account, unsubscribe in one click.
Site address
11800 SW 147TH AVE.
City
MIAMI
State
FL
ZIP
33169
Mailing
1151 NW 159TH DR., MIAMI, FL 33169
Inspection type
Accident-driven (A)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Y
Opened
Closing conference
Case closed
Data loaded
NAICS code
000000
SIC code (legacy)
1796
Employees
4
Ownership type
A
Industry flags
Construction safety.

1 citation on file for this inspection.

5(a)(1)

Serious 1 instance 1 exposed
Issued
Dec 16, 1986
Abate by
Dec 20, 1986
Penalty
Initial $560 · Current $560
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
a) On or about August 15, 1986, an employee working in an elevator shaft
(pit area) at 11800 SW 147th avenue, Miami, FL 33169, was exposed to
the hazard of being struck by the cab (car) of the elevator when the
cab of the elevator was not supported, braced, cribbed or blocked to
ensure it would not drop.
Among other methods one feasible and acceptable abatement method to
correct this hazard is to ensure that jack stands, blocking or cribbing
is installed underneath the cab to assure employees safety while working
between pinch points or in the pit area of the elevator shaft.
Recent events (2)
  • · 2 (S) $560.00
  • · Z (S) $560.00

View Otis Elevator Company's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 101552255.