OSHA Inspection: GAMMA CONSTRUCTION INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of GAMMA CONSTRUCTION INC. in 4950 SW 70TH AVE., MIAMI, FL 33155 (NAICS 000000). OSHA activity number 101555480.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Gamma Construction INC. — free Get an email when a new federal OSHA severe-injury report for Gamma Construction INC. is published. One employer, no account, unsubscribe in one click.
Site address
4950 SW 70TH AVE.
City
MIAMI
State
FL
ZIP
33155
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Data loaded
NAICS code
000000
SIC code (legacy)
1799
Employees
25
Ownership type
A

11 citations on file for this inspection.

5(a)(1)

Serious 1 instance 7 exposed
Issued
Nov 12, 1986
Abate by
Nov 15, 1986
Penalty
Initial $540 · Current $540
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
a) The hazard of being struck by falling trusses at Building No. 8 of
4950 SW 72nd Avenue, Miami, FL 33155: in that adequate and continuous
lateral bracing and proper diagonal bracing was not used to prevent
toppling and dominoing of erected trusses. Bracing through chords
laterally and cross bracing was not provided to ensure that trusses
were esecure in a straight and plumb position. Some trusses exhibited
evidence of buckling on or about October 3, 1986.
Among other methods one feasible and acceptable abatement method to
correct this hazard is to install bracing in accordance with the Truss
Plate Institute. BWI-76. Bracing Wood Trusses Commentary and
Recommendations.

1926.21 B02

Other-than-serious 1 instance 7 exposed
Issued
Nov 12, 1986
Abate by
Nov 15, 1986

1926.404 B01 I

Other-than-serious 1 instance 7 exposed
Issued
Nov 12, 1986
Abate by
Nov 15, 1986

1926.405 A02 III

Other-than-serious 1 instance 7 exposed
Issued
Nov 12, 1986
Abate by
Nov 15, 1986

1926.450 B12

Other-than-serious 1 instance 7 exposed
Issued
Nov 12, 1986
Abate by
Nov 15, 1986

1926.450 B12

Other-than-serious 1 instance 7 exposed
Issued
Nov 12, 1986
Abate by
Nov 15, 1986

1926.500 D01

Other-than-serious 1 instance 7 exposed
Issued
Nov 12, 1986
Abate by
Nov 15, 1986

1926.500 E01 II

Other-than-serious 1 instance 7 exposed
Issued
Nov 12, 1986
Abate by
Nov 15, 1986

1926.500 E01 III

Other-than-serious 1 instance 7 exposed
Issued
Nov 12, 1986
Abate by
Nov 15, 1986

1926.500 F01 IV

Other-than-serious 1 instance 7 exposed
Issued
Nov 12, 1986
Abate by
Nov 15, 1986

1926.501 F

Other-than-serious 1 instance 7 exposed
Issued
Nov 12, 1986
Abate by
Nov 17, 1986