Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: PERFCO WIRELINE, INC.

Accident-driven inspection · Safety discipline

On , OSHA opened an accident-driven safety inspection of PERFCO WIRELINE, INC. in SEC.23 TWP.205 RG.13E, HOUMA, LA 70397 (NAICS 000000). OSHA activity number 101640597.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Perfco Wireline, INC. for free Get an email when a new federal OSHA severe-injury report for Perfco Wireline, INC. is published. One employer, no account, unsubscribe in one click.
Site address
SEC.23 TWP.205 RG.13E
City
HOUMA
State
LA
ZIP
70397
Mailing
P. O. BOX 3130, HOUMA, LA 70361
Inspection type
Accident-driven (A)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Data loaded
NAICS code
000000
SIC code (legacy)
1389
Employees
3
Ownership type
A

5 citations on file for this inspection.

5(a)(1)

Serious 1 instance 3 exposed
Issued
Nov 18, 1987
Abate by
Nov 21, 1987
Penalty
Initial $350 · Current $120 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
a) Before perforating operations began on Blake Rig #6 on LL&E Well #1,
potential voltage differentials between the skid unit, the drilling
rig, and the well head were not checked: and the skid unit, the
drilling rig and the well head were not positively bonded together,
exposing employee(s) to the hazard of explosion.
One feasible and acceptable method of abatement would be to check the
voltage differential with an appropriate meter between the skid unit,
drilling rig, and the well head and to electrically bond together with
.rounding straps the skid unit, drilling rig, and well head.
Recent events (2)
  • · I (S) $120.00
  • · Z (S) $350.00

1910.109 E01 VII

Serious 1 instance 3 exposed
Issued
Nov 18, 1987
Abate by
Nov 21, 1987
Penalty
Initial $350 · Current $120 Reduced
Recent events (2)
  • · I (S) $120.00
  • · Z (S) $350.00

1910.109 E04 VIII

Serious 1 instance 3 exposed
Issued
Nov 18, 1987
Abate by
Nov 18, 1987
Penalty
Initial $350 · Current $120 Reduced
Recent events (2)
  • · I (S) $120.00
  • · Z (S) $350.00

1904.2 A

Other-than-serious 1 instance 11 exposed
Issued
Nov 18, 1987
Abate by
Dec 16, 1987
Recent events (2)
  • · I (O)
  • · Z (O)

1910.304 F04

Other-than-serious 1 instance 31 exposed
Issued
Nov 18, 1987
Abate by
Nov 23, 1987

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 101640597.