Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,871Inspections Most recent open 2026-07-30 Last loaded 2026-08-03

OSHA Inspection: ROGER BRAUN ASSOCIATES

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of ROGER BRAUN ASSOCIATES in 4088 NW 90TH AVENUE, SUNRISE, FL 33351 (NAICS 000000). OSHA activity number 101715894.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Roger Braun Associates for free Get an email when a new federal OSHA severe-injury report for Roger Braun Associates is published. One employer, no account, unsubscribe in one click.
Site address
4088 NW 90TH AVENUE
City
SUNRISE
State
FL
ZIP
33351
Mailing
421 CLUB PLACE, DULUTH, GA 30136
Inspection type
Unprogrammed Related (G)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Data loaded
NAICS code
000000
SIC code (legacy)
1751
Employees
5
Ownership type
A
Industry flags
Construction safety.

2 citations on file for this inspection.

5(a)(1)

Serious Gravity 05 1 instance 2 exposed
Issued
May 3, 1991
Abate by
May 8, 1991
Penalty
Initial $150 · Current $150
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not furnish employment and a place of employment which
were free from recognized hazards that were causing or likely to cause
death or serious physical harm to employees in that employees were
exposed to:
(a)  Wood roof trusses installed at 4088 NW 90 Avenue in
Sunrise, FL 33351 on the clubhouse, were not braced adequate-
ly on February 25, 1991 to prevent a potential truss col-
lapse; exposing employees to being struck or crushed by
falling trusses.
The following deficiencies were found:
(1)  The end trusses had no bracing to the ground.
(2)  There was no continuous lateral bracing for the
40-foot length of the building.
(3)  There was no diagonal bracing in the plane of the
web members.
(4)  End members exhibited evidence of leaning outward.
The hazard of truss collapse may be corrected by bracing the
trusses laterally, diagonally, and on their ends to the
ground as recommended by the Truss Plate Institute in "Brac-
ing Wood Trusses: Commentary and Recommendations BWT-76".

1926.403 B01

Serious Gravity 05 2 instances 1 exposed
Issued
May 3, 1991
Abate by
May 6, 1991
Penalty
Initial $150 · Current $150

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 101715894.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.