SUNRISE, FL ·
OSHA Inspection: ROGER BRAUN ASSOCIATES
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of ROGER BRAUN ASSOCIATES in 4088 NW 90TH AVENUE, SUNRISE, FL 33351 (NAICS 000000). OSHA activity number 101715894.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ROGER BRAUN ASSOCIATES
- Site address
- 4088 NW 90TH AVENUE
- City
- SUNRISE
- State
- FL
- ZIP
- 33351
- Mailing
- 421 CLUB PLACE, DULUTH, GA 30136
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 1751
- Employees
- 5
- Ownership type
- A
- Industry flags
- Construction safety.
Citations
2 citations on file for this inspection.
5(a)(1)
- Issued
- May 3, 1991
- Abate by
- May 8, 1991
- Penalty
- Initial $150 · Current $150
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: (a) Wood roof trusses installed at 4088 NW 90 Avenue in Sunrise, FL 33351 on the clubhouse, were not braced adequate- ly on February 25, 1991 to prevent a potential truss col- lapse; exposing employees to being struck or crushed by falling trusses. The following deficiencies were found: (1) The end trusses had no bracing to the ground. (2) There was no continuous lateral bracing for the 40-foot length of the building. (3) There was no diagonal bracing in the plane of the web members. (4) End members exhibited evidence of leaning outward. The hazard of truss collapse may be corrected by bracing the trusses laterally, diagonally, and on their ends to the ground as recommended by the Truss Plate Institute in "Brac- ing Wood Trusses: Commentary and Recommendations BWT-76".
1926.403 B01
- Issued
- May 3, 1991
- Abate by
- May 6, 1991
- Penalty
- Initial $150 · Current $150
More inspections in this industry (NAICS 000000)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 101715894.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.