MILWAUKEE, WI —
OSHA Inspection: TAYLOR INDUSTRIAL VAC INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of TAYLOR INDUSTRIAL VAC INC. in 2711 W. TOWNSEND, MILWAUKEE, WI 53216 (NAICS 000000). OSHA activity number 102354149.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TAYLOR INDUSTRIAL VAC INC.
- Site address
- 2711 W. TOWNSEND
- City
- MILWAUKEE
- State
- WI
- ZIP
- 53216
- Mailing
- P.O. BOX 16579, MILWAUKEE, WI 53216
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 4212
- Employees
- 9
- Ownership type
- A
- Industry flags
- Manufacturing safety.
Citations
3 citations on file for this inspection.
5(a)(1)
- Issued
- Jul 13, 1990
- Abate by
- Aug 14, 1990
- Penalty
- Initial $160 · Current $160
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: (a) A confined space entry program was not established to protect employees who were exposed to hazards created by spaces with res- tricted entry and exit, a primary function other than that of human occupancy and that might contain potential hazards such as oxygen deficiency, overexposure to toxic contaminants, and flammable atmos phere. The american National Standards Institute Safety requirement for confined spaces (ANS12 2117.1-1989) contains acceptable methods of compliance which include the following: 1) Survey of all operations to identify confined spaces. 2) Hazard identification in each confined space. 3) Evaluation of hazards found by a qualified person. 4) Classifying the space as permit or non-permit required. 5) Development of a permit system for all entries that authorizes work and appropriate protective measures. 6) Atmospheric testing prior to entry. 7) Attendants stationed outside the confined space in constant communication with the occupants of the space. 8) Isolation of all energy sources within the space. 9) Ventilation of the confined space. 10) Proper personal protective equipment, such as respiratory protection. 11) An emergency response plan for timely rescue. 12) Training of all personnel involved in confined space entry. 13) Periodic assessment of the program to ensure its continued effectiveness.
1910.1200 E01
- Issued
- Jul 13, 1990
- Abate by
- Jul 20, 1990
1910.1200 H
- Issued
- Jul 13, 1990
- Abate by
- Aug 4, 1990
More inspections at Taylor Industrial VAC INC.
View Taylor Industrial VAC INC.'s full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 102354149.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.