MEQUON, WI —
OSHA Inspection: MICHEL CONSTRUCTION
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of MICHEL CONSTRUCTION in 1523 MEQUON ROAD, MEQUON, WI 53092 (NAICS 000000). OSHA activity number 102355740.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MICHEL CONSTRUCTION
- Site address
- 1523 MEQUON ROAD
- City
- MEQUON
- State
- WI
- ZIP
- 53092
- Mailing
- 1417 N. WISCONSIN STREET, PORT WASHINGTON, WI 53074
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 1751
- Employees
- 5
- Ownership type
- A
- Industry flags
- Construction safety.
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Mar 14, 1990
- Abate by
- Mar 17, 1990
- Penalty
- Initial $720 · Current $365 Reduced
General-duty citation text
Section 5 (a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: a) On February 5, 1990 employees(s) were exposed to a potential fall and/or crushing hazard which was caused by inadequate bracing and support of roof trusses. A feasible method of abatement includes but is not limited to: adequate bracing of continuous lumber (no less than 2" x 4" nominal) running parallel to the ridge line and spaced 8' to 10' apart in the top chord and bottom chord planes. These are to be supplemented with diagonal bracing (no less than 2" x 4" nominal) spaced no more than 20 feet apart in the top and bottom chord planes and among the web members. These are to be sucured with 16D nails.
Recent events (2)
- — I (S) $365.00
- — Z (S) $720.00
More inspections in this industry (NAICS 000000)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 102355740.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.