Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MICHEL CONSTRUCTION

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of MICHEL CONSTRUCTION in 1523 MEQUON ROAD, MEQUON, WI 53092 (NAICS 000000). OSHA activity number 102355740.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Michel Construction — free Get an email when a new federal OSHA severe-injury report for Michel Construction is published. One employer, no account, unsubscribe in one click.
Establishment
MICHEL CONSTRUCTION
Site address
1523 MEQUON ROAD
City
MEQUON
State
WI
ZIP
53092
Mailing
1417 N. WISCONSIN STREET, PORT WASHINGTON, WI 53074
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Data loaded
NAICS code
000000
SIC code (legacy)
1751
Employees
5
Ownership type
A
Industry flags
Construction safety.

1 citation on file for this inspection.

5(a)(1)

Serious Gravity 09 1 instance 2 exposed
Issued
Mar 14, 1990
Abate by
Mar 17, 1990
Penalty
Initial $720 · Current $365 Reduced
Section 5 (a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
a) On February 5, 1990 employees(s) were exposed to a potential fall
and/or crushing hazard which was caused by inadequate bracing and
support of roof trusses.
A feasible method of abatement includes but is not limited to: adequate
bracing of continuous lumber (no less than 2" x 4" nominal) running
parallel to the ridge line and spaced 8' to 10' apart in the top chord
and bottom chord planes. These are to be supplemented with diagonal
bracing (no less than 2" x 4" nominal) spaced no more than 20 feet apart
in the top and bottom chord planes and among the web members. These are
to be sucured with 16D nails.