Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,124Inspections Most recent open 2026-08-25 Last loaded 2026-08-28

OSHA Inspection: QUEEN CITY STEEL TREATING CO.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of QUEEN CITY STEEL TREATING CO. in 2980 SPRING GROVE AVE., CINCINNATI, OH 45225 (NAICS 000000). OSHA activity number 102460268.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Queen City Steel Treating CO. for free Get an email when a new federal OSHA severe-injury report for Queen City Steel Treating CO. is published. One employer, no account, unsubscribe in one click.
Site address
2980 SPRING GROVE AVE.
City
CINCINNATI
State
OH
ZIP
45225
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
Union (Y)
Opened
Closing conference
Case closed
Data loaded
NAICS code
000000
SIC code (legacy)
3398
Employees
62
Ownership type
Private (A)
Industry flags
Manufacturing health.

1 citation on file for this inspection.

5(a)(1)

Serious Gravity 03 1 instance 3 exposed
Issued
Jun 19, 1992
Abate by
Sep 1, 1992
Penalty
Initial $1,500 · Current $1,000 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not furnish employment and a place of employment which
were free from recognized hazards that were causing or likely to cause
death or serious physical harm to employees in that employees were
exposed to:
a)  Employees in plant 2 were exposed fire and explosion hazards due   t
the potential ignition of accumulated fuel gases in furnace # 132 under
abnormal conditions.  Among other methods, one feasible and acceptable
abatement method to correct this hazard is the installation of a control
system which includes a ventilation purge cycle and flame super-vision
capacity with automatic gas line shut down for flame failure conditions
(such as required by NFPA 86B-1971 Articles, 550 and 560, NFPA 86B-1974
Articles 510 and NFPA 86A-1977, Chapter 4.)
Recent events (2)
  • · I (S) $1000.00
  • · Z (S) $1500.00

View Queen City Steel Treating CO.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 102460268.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.