MEDFORD, WI —
OSHA Inspection: ENERQUIP, INC.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of ENERQUIP, INC. in 611 NORTH ROAD, MEDFORD, WI 54451 (NAICS 000000). OSHA activity number 102475274.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ENERQUIP, INC.
- Site address
- 611 NORTH ROAD
- City
- MEDFORD
- State
- WI
- ZIP
- 54451
- Mailing
- P. O. BOX 368, MEDFORD, WI 54451
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 3443
- Employees
- 22
- Ownership type
- A
- Industry flags
- Manufacturing health.
Citations
5 citations on file for this inspection.
5(a)(1)
- Issued
- Dec 23, 1991
- Abate by
- Jan 27, 1992
- Penalty
- Initial $625 · Current $625
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The %% employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: (a) An employee entered an enclosed cylinder/ vessel to apply an epoxy coating to the inside of the vessel. The alleged violations below have been grouped because they involve similar or related hazards that may increase the potential for injury resulting from an accident. Among other methods, one feasible and acceptable abatement method to correct these hazards is to establish and enforce an adequate plant confined space entry procedure such as that stipulated by ANSI Z117.1- 1989. American National Standard for Working in Tanks and Other Confined Spaces. Essential elements of this confined space entry procedure would include: 1. Hazard identification. Identify and evaluate each hazard of the permit spaces, including determination of severity; 2. Hazard control. Establish and implement the means, procedures and practices by which the permit spaces can be entered safely; 3. Permit system. Establish a written permit system for the proper preparation, issuance and implementation of entry permits. 4. Employee information. Signs shall be posted near permit spaces to notify employees what hazards may be presnet and that only authorized entrants may enter the permit spaces; 5. Prevention of unauthorized entry. Prevent unauthorized employee entry through such measures as training or by posting signs and barriers, as necessary; 6. Employee training. Train employees so that attedants, authorized entrants and personel authorizing or in charge of entry can work safely in and around the permit space; 7. Equipment. Provide, maintain and ensure the proper use of the equipment necessary for safe entry, including testing, monitoring, communication and personal protective equipment. 8. Rescue. Ensure that the procedures and equipment necessary to rescue entrants from permit spaces are implemented and provided; 9. Protection from external hazards. Ensure that all pedestrian, vehicle or other barriers necessary to protect entrants from external hazards are provided; 10. Duty to other employers. Ensure that, when an employer, such as a contractor, plans to send employees into a permit space which is under the control of another employer (host employer), the host employer provides the contractor with available information on permit space hazards; on efforts to comply with this standard; and on any other workplace hazards, safety rules and emergency procedures of which the contractor needs to be aware of.
1910.252 B04 IV
- Issued
- Dec 23, 1991
- Abate by
- Jan 6, 1992
1904.2 A
- Issued
- Dec 23, 1991
- Abate by
- Jan 6, 1992
1910.147 C01
- Issued
- Dec 23, 1991
- Abate by
- Jan 27, 1992
1910.1200 E01 I
- Issued
- Dec 23, 1991
- Abate by
- Jan 27, 1992
More inspections at Enerquip, INC.
View Enerquip, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 102475274.