WATERTOWN, WI ·
OSHA Inspection: WISCONSIN FURNITURE, LLC DBA THE CUSTOM SHOPPE
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of WISCONSIN FURNITURE, LLC DBA THE CUSTOM SHOPPE in 300 AIR PARK DRIVE, WATERTOWN, WI 53094 (NAICS 000000). OSHA activity number 102513520.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- WISCONSIN FURNITURE, LLC DBA THE CUSTOM SHOPPE
- Site address
- 300 AIR PARK DRIVE
- City
- WATERTOWN
- State
- WI
- ZIP
- 53094
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 2834
- Employees
- 95
- Ownership type
- A
- Industry flags
- Manufacturing health.
Citations
4 citations on file for this inspection.
5(a)(1)
- Issued
- Apr 6, 1990
- Abate by
- Nov 1, 1990
- Penalty
- Initial $640 · Current $320 Reduced
General-duty citation text
Section 5(A)(1) of the OccupationlL Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: a) Employees were exposed to the potential hazards of oxygen deficiency and/or toxic vapors when working in the chlorophyll mix tank. b) Employees were exposed to the potential hazards of oxygen deficiency and/or toxic vapors when required to enter process tanks for cleaning or repair. Among other methods, one feasible and acceptable abatement method to correct these hazards is to establish and enforce an adequate plant confined space entry procedure such as theat stipulated by ANSI Z117.1-1977, American National Standard for Working in Tanks and and Other Confined Spaces. Essential elements of this confined space entry procedure would include: 1) Written procedures covering a permit system, isolation, ventilation, atmospheric testing, rescue procedures and employee training. 2) The completion and posting of a confined space entry permit which requires authorization and approval in writting that specifies, the location and type of work to be done and certifies that all existing and potential hazards have been evaluated by a qualified person and necessary protective measures have been taken to ensure the safety of each worker. 3) Isolation of the confined space to preclude the energy of hazardous materials and/or activation of energy sources (e.g., electrical, mechanical, hydraulic, etc.). Methods which can be used to prevent the entry of hazardous materials into the confined space include: removing pipe sections, blanking pipelines or closing and locking open a drain valve leading to the atmosphere between the two closed valves (double block & bleed). Methods which can be used to prevent activation of energy sources affecting the confined space include: locking out electrical line switches to equipment controlling moving hazards, dissipating stored energy in capacitors, air, steam, water and other pressure lines and blocking or repositioning springs, elevated machine members and rotating flywheels to prevent the release of stored energy. 4) Mechanical(s) ventilation of the confined space prior to entry and continued ventilation to provide a safe atmosphere, when determined necessary as described in (2) above. 5) Testing the atmosphere of the confined space prior to entry and on a regular basis for the presence of sufficient oxygen (19.5% or greater) and absence of hazardous levels of toxic, flammable or combustible gases or vapors, when determined necessary as described in (2) above. 6) Emergency rescue procedures with a requirement that trained personnel are available and stationed outside the confined space with proper equipment to provide for rescue of person(s) entering the space. Such equipment must include safety harness(es) and lifeline(s) with provisions for hoisting employees from the confined space. If entry is required for rescue, the rescuing employee(s) must be equipped with approved supplied air respiratory equipment with escape provisions or self-contained breathing apparatus (SCBA) plus other appropriate personal protective equipment. 7) Training of any and all employees required to enter the confined spaces. This training shall include procedures required prior to entry, the hazards associated with work in confined spaces as well as emergency rescue.
Recent events (2)
- · I (S) $320.00
- · Z (S) $640.00
1910.25 D01 X
- Issued
- Apr 6, 1990
- Abate by
- Apr 9, 1990
Recent events (2)
- · I (O)
- · Z (O)
1910.120 Q01
- Issued
- Apr 6, 1990
- Abate by
- Nov 1, 1990
Recent events (2)
- · I (O)
- · Z (O)
1910.147 C04 I
- Issued
- Apr 6, 1990
- Abate by
- Nov 1, 1990
Recent events (2)
- · I (O)
- · Z (O)
More inspections in this industry (NAICS 000000)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 102513520.