NEENAH, WI ·
OSHA Inspection: CONTRX INDUSTRIES
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CONTRX INDUSTRIES in 1377 KIMBERLY DR., NEENAH, WI 54956 (NAICS 000000). OSHA activity number 102539798.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CONTRX INDUSTRIES
- Site address
- 1377 KIMBERLY DR.
- City
- NEENAH
- State
- WI
- ZIP
- 54956
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (N)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 3536
- Employees
- 30
- Ownership type
- Private (A)
- Industry flags
- Manufacturing safety.
Citations
8 citations on file for this inspection.
5(a)(1)
- Issued
- Oct 7, 1988
- Abate by
- Oct 17, 1988
- Penalty
- Initial $420 · Current $420
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The %% employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: a) Inadvertent activation of the rotary grinder while an employee was inside of the machine performing maintenance work. Among other methods, one feasible and acceptable abatement method to correct this hazard is to establish and enforce an adequate plant lockout procedure such as that stipulated by ANSI Z244.1-1982, Section 4 and 5, American National Standard of Minimum Safety Requirements for Lockout/Tagout of Energy Sources for Personnel Protection. Essential elements of the lockout procedure would include: 1) Open and lock out the main power disconnect for the machine and bleed off any residual energy. 2) Provide each potentially exposed employee working in the area with separate lock and key to be placed on the lockout means. 3) Establish a written lockout policy, including procedures to be followed and training for all affected employees, both maintenance and operational crews. 4) Periodically evaluate the program and strictly enforce all of its provisions.
1910.107 B05 I
- Issued
- Oct 7, 1988
- Abate by
- Oct 17, 1988
- Penalty
- Initial $240 · Current $240
1910.107 B05 I
- Issued
- Oct 7, 1988
- Abate by
- Oct 26, 1988
1910.107 F03
- Issued
- Oct 7, 1988
- Abate by
- Oct 19, 1988
1910.215 B09
- Issued
- Oct 7, 1988
- Abate by
- Nov 14, 1988
1910.215 B09
- Issued
- Oct 7, 1988
- Abate by
- Oct 26, 1988
1910.252 A02 IVC
- Issued
- Oct 7, 1988
- Abate by
- Oct 24, 1988
1910.305 G02 II
- Issued
- Oct 7, 1988
- Abate by
- Oct 26, 1988
More inspections at Contrx Industries
View Contrx Industries's full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 102539798.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.