SHAWANO, WI —
OSHA Inspection: AARROW ELECTRIC IRON CASTINGS, INC.
Accident-driven inspection · Safety discipline
At a glance
On , OSHA opened an accident-driven safety inspection of AARROW ELECTRIC IRON CASTINGS, INC. in 2900 E. RICHMOND ST., SHAWANO, WI 54166 (NAICS 000000). OSHA activity number 102542768.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AARROW ELECTRIC IRON CASTINGS, INC.
- Site address
- 2900 E. RICHMOND ST.
- City
- SHAWANO
- State
- WI
- ZIP
- 54166
What kind of inspection was it?
- Inspection type
- Accident-driven (A)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- Yes
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 3321
- Employees
- 40
- Ownership type
- A
- Industry flags
- Manufacturing safety.
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Apr 11, 1989
- Abate by
- Apr 20, 1989
- Penalty
- Initial $1,000 · Current $700 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The %% employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: a) Inadvertent activation of the COLD BOX TILT MECHANISM on the REDFORD CB26SA AUTO CORE-MACHINE, serial number: 114-CB26SA-AC: Employees performed maintenance and changed the COLD BOX DIES on the machine while the machine was not electrically shutdown and locked- out and the TILT mechanism was not blocked. Among other methods, one feasible and acceptable abatement method to correct this hazard is to establish and enforce an adequate plant lockout procedure such as that stipulated by ANSI Z244.1-1982, Section 4 & 5 American National Standard of Minimum Safety Requirements for lock-out/tagout of Energy Sources for Personnel Protection. Essential elements of the lock-out procedure would include: 1) Open and lock-out the main power supply disconnect for the machine and bleed off residual energy. 2) Provide each potentially exposed employee working in the area with a separate lock and key to be placed on the lock-out means 3) Establish a written lock-out policy, including procedures to be followed and training for all affected employees, both maintenance and operational crews. 4) Periodically evaluate the program and strickly enforce all of its provisions.
Recent events (2)
- — F (S) $700.00
- — Z (S) $1000.00
More inspections at Aarrow Electric Iron Castings, INC.
View Aarrow Electric Iron Castings, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 102542768.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.