CARLISLE, PA —
OSHA Inspection: CARLISLE SYNTEC SYSTEMS/DIVISION OF CARLISLE CORP.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of CARLISLE SYNTEC SYSTEMS/DIVISION OF CARLISLE CORP. in 1295 RITNER HIGHWAY, CARLISLE, PA 17013 (NAICS 000000). OSHA activity number 102704012.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CARLISLE SYNTEC SYSTEMS/DIVISION OF CARLISLE CORP.
- Site address
- 1295 RITNER HIGHWAY
- City
- CARLISLE
- State
- PA
- ZIP
- 17013
- Mailing
- P.O. BOX 7000, CARLISLE, PA 17013
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 3069
- Employees
- 520
- Ownership type
- A
Citations
6 citations on file for this inspection.
5(a)(1)
- Issued
- Oct 21, 1993
- Abate by
- Nov 23, 1993
- Penalty
- Initial $1,500 · Current $750 Reduced
83208330
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to Heat Stress: (a) Plant 4, F-270 Mixer Area - A compounder employee was exposed to excessive heat from the clean out operations conducted in the F-270 Mixer Hopper. The Wet Bulb Globe Temperature (WBGT) was found to be 24.5 degrees Celsius (C). This was 1.408 times the Threshold Limit Value (TLV) found in the American Conference of Governmental Hygienists (ACGIH) Threshold Limit Values for Chemical Substances and Physical Agents and Biological Exposure Indices, 1992-1993. The sample was taken inside the Mixer Chamber where the employee was conducting cleaning activities for approximately 135 minutes, on or about August 11, 1993. (b) Plant 4, F-270 Mixer Area - A Mill Room Service employee was exposed to excessive heat from the clean out operations conducted in the F-270 Mixer Gate. The Wet Bulb Globe Temperature (WBGT) was found to be 22.9 degrees Celsius (C). This was 1.316 times the Threshold Limit Value (TLV) found in the American Conference of Governmental Hygienists (ACGIH) Threshold Limit Values for Chemical Substances and Physical Agents and Biological Exposure Indices, 1992-1993. The sample was taken inside the Mixer Gate area where the employee was conducting cleaning activities for approximately 46 minutes, on or about August 11, 1993. (c) Plant 4, F-270 Mixer Area - A clean-out employee was exposed to excessive heat from the clean out operations conducted in the F-270 Mixer Gate. The Wet Bulb Globe Temperature (WBGT) was found to be 23.4 degrees Celsius (C). This was 1.342 times the Threshold Limit Value (TLV) found in the American Conference of Governmental Hygienists (ACGIH) Threshold Limit Values for Chemical Substances and Physical Agents and Biological Exposure Indices, 1992-1993. The sample was taken inside the Mixer Chamber where the employee was conducted cleaning activities for approximately 135 minutes, on or about August 11, 1993. FEASIBLE ENGINEERING CONTROLS MAY INCLUDE, BUT ARE NOT LIMITED TO: 1. Institute a "Work-Rest" Regiment to allow employees time to recover from heat stress conditions. A Permissible Work - Rest Regimen may be as follows: ACTIVITY PERMISSIBLE WBGT Continuous Work 16.5 0 Celsius - 61.7 0 Fahrenheit 75Work 25Rest 17.4 0 Celsius - 63.3 0 Fahrenheit 50Work 50Rest 19.4 0 Celsius - 66.9 0 Fahrenheit 25Work 75Rest 21.5 0 Celsius - 70.7 0 Fahrenheit 2. Provide and require employee wear of air-supplied respirator systems while in F-270 mixer. 3. Provide and require employee wear of cooling vests or jackets while in the F-270 Mixer.
Recent events (2)
- — I (S) $750.00
- — Z (S) $1500.00
1910.146 D04 VIII
- Issued
- Oct 21, 1993
- Abate by
- Nov 3, 1993
- Penalty
- Initial $1,125 · Current $565 Reduced
Recent events (2)
- — I (S) $565.00
- — Z (S) $1125.00
1910.146 D09
- Issued
- Oct 21, 1993
- Abate by
- Nov 23, 1993
- Penalty
- Initial $1,875 · Current $935 Reduced
Recent events (2)
- — I (S) $935.00
- — Z (S) $1875.00
1910.146 G01
- Issued
- Oct 21, 1993
- Abate by
- Nov 23, 1993
- Penalty
- Initial $1,875 · Current $1,440 Reduced
Recent events (2)
- — I (S) $1440.00
- — Z (S) $1875.00
1910.242 B
- Issued
- Oct 21, 1993
- Abate by
- Oct 31, 1993
- Penalty
- Initial $2,625 · Current $1,310 Reduced
Recent events (2)
- — I (S) $1310.00
- — Z (S) $2625.00
1910.146 F07
- Issued
- Oct 21, 1993
- Abate by
- Nov 3, 1993
More inspections at Carlisle Syntec Systems/Division of Carlisle Corp.
View Carlisle Syntec Systems/Division of Carlisle Corp.'s full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 102704012.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.