On , OSHA opened a referral safety inspection of KEYSTONE BUILDING MAINTENANCE in 107-115 SOUTH 2ND STREET, PHILADELPHIA, PA 19106 (NAICS 000000). OSHA activity number 102840972.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Keystone Building Maintenance for free Get an email when a new federal OSHA severe-injury report for Keystone Building Maintenance is published. One employer, no account, unsubscribe in one click.
Site address
107-115 SOUTH 2ND STREET
City
PHILADELPHIA
State
PA
ZIP
19106
Mailing
1310 SPRUCE STREET, PHILADELPHIA, PA 19107
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (N)
Opened
Closing conference
Case closed
Data loaded
NAICS code
000000
SIC code (legacy)
7349
Employees
3
Ownership type
Private (A)

7 citations on file for this inspection.

5(a)(1)

Serious Gravity 04 1 instance 2 exposed
Issued
Aug 24, 1992
Abate by
Aug 28, 1992
Penalty
Initial $875 · Current $525 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not furnish employment and a place of employment which
were free from recognized hazards that were causing or likely to cause
death or serious physical harm to employees in that employees were
exposed to a fall hazard up to five stories:
a)  107-115 S. 2nd St. - Employees were not using lifelines
attached to a completely separate fall arresting system.
Observed 6/2/92
NOTE:  One useful means of abatement among other, would be to
install a life line completely separate fall arresting system and
being utilized by employees.
Recent events (2)
  • · I (S) $525.00
  • · Z (S) $875.00

5(a)(1)

Serious Gravity 03 1 instance 2 exposed
Issued
Aug 24, 1992
Abate by
Aug 28, 1992
Penalty
Initial $875 · Current $525 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death or
serious physical harm to employees in that there were no method being used
by the employer to determine if roof attachment points used to anchor the
primary support systems of "Sky Genies" were capable of supporting at least
5000 pounds:
a)  107-115 S. 2nd St. - Two employees engaged in window washing
activities using a "Sky Genie" were using iron railings to support
the suspension system.
NOTE:  One useful and feasible method of abatement, among, others
would be to load test the attachment points for the primary
support and lifeline prior to the start of the job.
Recent events (2)
  • · I (S) $525.00
  • · Z (S) $875.00

5(a)(1)

Serious Gravity 04 1 instance 2 exposed
Issued
Aug 24, 1992
Abate by
Oct 8, 1992
Penalty
Initial $875 · Current $525 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not furnish employment and a place of employment which
were free from recognized hazards that were causing or likely to cause
death or serious physical harm to employees in that two employees
engagged in window washing activities using "Sky Genie" systems were
exposed to a fall hazard of up to 5 floors since employees had not been
adequately trained in the use of this system:
a) 107-115 S. 2nd St. - Employees have not been adequately trained
in the use of "Sky Genies" in the employees were observed without
life lines attached to a completely separate fall arresting
system.  Observed 6/2/92
NOTE:  One useful and feasible means of abatement among other,
would be to ensure all window cleaners are trained in and familiar
with safety working from "Sky Genie" and be trained in the proper
safety use of the equipment in accordance with manufactures com-
mendations and OSHA Guildelines.
Recent events (2)
  • · I (S) $525.00
  • · Z (S) $875.00

5(a)(1)

Serious Gravity 04 1 instance 2 exposed
Issued
Aug 24, 1992
Abate by
Aug 28, 1992
Penalty
Initial $875 · Current $525 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
%%
employer did not furnish employment and a place of employment which
were free from recognized hazards that were causing or likely to cause
death or serious physical harm to employees in that there were no
pre-work rescue plan in place for employees performing window washing
work from a "Sky Genie System":
a)  107-115 S. 2nd St., Phila, Pa. 19106 - Employees engged in
window cleaning activities were not protected by a pre-work rescue
plan for self rescue.  Observed 6/2/92
ABATEMENT NOTE:  One useful and feasible method of abatement among
others, would be to design and implement a rescue system which
does not rely on the suspended employee for rescue in the event an
accident occur.
Recent events (2)
  • · I (S) $525.00
  • · Z (S) $875.00

1910.132 A

Serious Gravity 03 1 instance 1 exposed
Issued
Aug 24, 1992
Abate by
Aug 28, 1992
Penalty
Initial $875 · Current $525 Reduced
Recent events (2)
  • · I (S) $525.00
  • · Z (S) $875.00

1910.1200 E01

Serious Gravity 02 1 instance 2 exposed
Issued
Aug 24, 1992
Abate by
Oct 8, 1992
Penalty
Initial $200 · Current $120 Reduced
Recent events (2)
  • · I (S) $120.00
  • · Z (S) $200.00

1910.1200 H

Serious Gravity 03 1 instance 2 exposed
Issued
Aug 24, 1992
Abate by
Oct 8, 1992

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 102840972.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.