N. ROYALTON, OH ·
OSHA Inspection: HAWK REBUILDING, INC.
Accident-driven inspection · Safety discipline
At a glance
On , OSHA opened an accident-driven safety inspection of HAWK REBUILDING, INC. in 12126 YORK RD., N. ROYALTON, OH 44133 (NAICS 000000). OSHA activity number 103023230.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HAWK REBUILDING, INC.
- Site address
- 12126 YORK RD.
- City
- N. ROYALTON
- State
- OH
- ZIP
- 44133
What kind of inspection was it?
- Inspection type
- Accident-driven (A)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 7538
- Employees
- 13
- Ownership type
- A
Citations
4 citations on file for this inspection.
5(a)(1)
- Issued
- Oct 12, 1988
- Abate by
- Oct 15, 1988
- Penalty
- Initial $1,000 · Current $700 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The %% employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: The hazards of severe Lacerations, amputations multiple fractured bones and/or death, while working and performing duties in the south central engine rebuilding shop area of the plant premises. The aforementioned hazards were created by inserting compressed air, in excess of 150 psi, into non-pressurized fifty-five (55) gallong metal drums of anti-freeze solution, to siphon the liquid out of the drums. The hazards can be abated by, but not limited to, program including the following criteria: Among other methods, one feasible and acceptable method to correct this hazard is to prohibit transfer of liquids by pressurization of containers with compressed air as stipulated in Section 5-4.1.4 of NFPA 30-1987, Flammable and Combustlble Liquids Code, and substitue one or more of the following methods: Use a gravity drain system with the drum placed sideways on a drum rack (i.e. cradle) fitted with a self-closing valve in the bung hole. Drain liquids by means of an approved manually (hand) operated rotary mechanical pump inserted into the top bung hole, with the drum standing upright. Transfer liquids by pressure of inert gas, but only if controls, including pressure-relief devices, are provided to limit the pressure so it cannot exceed the design pressure of the container. (NOTE: This is the least recommended substitute).
Recent events (2)
- · I (S) $700.00
- · Z (S) $1000.00
1910.1200 E01
- Issued
- Oct 12, 1988
- Abate by
- Oct 15, 1988
- Penalty
- Initial $1,000 · Current $550 Reduced
Recent events (2)
- · I (S) $550.00
- · Z (S) $1000.00
1903.2 A01
- Issued
- Oct 12, 1988
- Abate by
- Nov 3, 1988
1904.2 A
- Issued
- Oct 12, 1988
- Abate by
- Nov 3, 1988
More inspections in this industry (NAICS 000000)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 103023230.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.