SHEBOYGAN FALLS, WI —
OSHA Inspection: ALDRICH CHEMICAL COMPANY, INC.
Accident-driven inspection · Safety discipline
At a glance
On , OSHA opened an accident-driven safety inspection of ALDRICH CHEMICAL COMPANY, INC. in 5485 CTY HWY V, SHEBOYGAN FALLS, WI 53085 (NAICS 000000). OSHA activity number 103052908.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ALDRICH CHEMICAL COMPANY, INC.
- Site address
- 5485 CTY HWY V
- City
- SHEBOYGAN FALLS
- State
- WI
- ZIP
- 53085
- Mailing
- 6000 N TEUTONIA, MILWAUKEE, WI 53209
What kind of inspection was it?
- Inspection type
- Accident-driven (A)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 2819
- Employees
- 105
- Ownership type
- A
Citations
2 citations on file for this inspection.
5(a)(1)
- Issued
- Mar 25, 1991
- Abate by
- Apr 29, 1991
- Penalty
- Initial $1,000 · Current $1,000
General-duty citation text
SECTION 5(A)(1) OF THE OCCUPATIONAL SAFETY AND HEALTH ACT OF 1970; THE EMPLOYER DID NOT FURNISH EMPLOYMENT AND A PLACE OF EMPLOYMENT WHICH WERE FREE FROM RECOGNIZED HAZARDS THAT WERE CAUSING OR LIKELY TO CAUSE DEATH OR SERIOUS PHYSICAL HARM TO EMPLOYEES IN THAT: A) WORKERS WERE EXPOSED TO THE HAZARDS OF BURNS, BROKEN BONES, CRUSHING, LACERATIONS, AND DEATH FROM THE UNCONTROLLED OR IMPROPER IGNITION OF THE FUEL AND AIR MIXTURES INVOLVING THE BRYAN CORPORATION STEAM AND BOILERS; THE SUPPLY GAS, AIR, WATER, STEAM, AND ELECTRICAL SERVICE LINES; AND THE STEAM BOILER CONTROL SYSTEMS. THE HAZARDS CAN BE REMOVED BY A PROGRAM THAT INCLUDES, BUT IS NOT LIMITED TO THE FOLLOWING ELEMENTS: 1) REVIEW THE WRITTEN PROCEDURE FOR START-UP OF FURNACES. THE PROCEDURE SHALL BE USED UPON DOCUMENTED INSTRUCTIONS PROVIDED BY THE INSTALLER AND/OR MANUFACTURER OF THE FURNACE AND ITS CONTROL SYSTEM. THE START-UP PROCEDURE SHALL BE EXPECTED TO INCLUDE ELEMENTS THAT INCLUDE: A) ASSURE THAT ALL OF THE GAS VALVES, ELECTRICAL SWITCHES, AND CONTROLS ARE POSITIONED AS REQUIRED. B) LIGHT THE PILOT LIGHT. C) DETERMINE THAT THE PILOT LIGHT IS BURNING AND THAT THE FLAME IS STABLE. D) OPEN GAS VALVES, SET SWITCHES, AND TAKE APPROPRIATE READINGS IN THE PRESCRIBED ORDER. E) IF ANY DEVIATIONS FROM THE PRESCRIBED START-UP ARE ENCOUNTERED, IMMEDIATELY USE THE DOCUMENTED EMERGENCY SHUTDOWN PROCEDURE AND NOTIFY MANAGEMENT. DO NOT BEGIN THE START-UP PROCEDURE UNTIL GIVEN SPECIFIC INSTRUCTIONS BY DESIGNATED RESPONSIBLE AUTHORITY.
1910.147 E03
- Issued
- Mar 25, 1991
- Abate by
- Mar 28, 1991
- Penalty
- Initial $800 · Current $800
More inspections at Aldrich Chemical Company, INC.
View Aldrich Chemical Company, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 103052908.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.