TOLEDO, OH —
OSHA Inspection: TOLEDO COKE CORP.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of TOLEDO COKE CORP. in 2563 FRONT ST., TOLEDO, OH 43605 (NAICS 000000). OSHA activity number 103056438.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TOLEDO COKE CORP.
- Site address
- 2563 FRONT ST.
- City
- TOLEDO
- State
- OH
- ZIP
- 43605
- Mailing
- P.O. BOX 50588, TOLEDO, OH 43605
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- Y
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 3312
- Employees
- 141
- Ownership type
- A
- Industry flags
- Manufacturing health.
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Jun 21, 1989
- Abate by
- Dec 29, 1989
- Penalty
- Initial $1,000 · Current $1,000
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: The level of illumination was inadequate on top of the coke ovens and on the push and coke side of the coke ovens in that employees were exposed to: Falls, resulting in possible fractures and/or severe burns from contact with hot surfaces, while working on top of coke ovens and on the push and coke side of the coke ovens due to inadequate illumination during night time work hours in several areas where employees were working, illuminations was measured to be less than two foot candles. Among other methods, one feasible and acceptable abatement method to correct this hazard is to increase the minimum levels of illumination for all areas/activities on the coke ovens to at least 20 foot candles, as stipulated by ANSI/IES RP7-1983, Practice for Industrial Lighting.
Recent events (2)
- — F (S) $1000.00
- — Z (S) $1000.00
More inspections at Toledo Coke Corp.
View Toledo Coke Corp.'s full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 103056438.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.