FINDLAY, OH ·
OSHA Inspection: DLM PLASTICS CORPORATION
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of DLM PLASTICS CORPORATION in 1530 HARVARD AVENUE, FINDLAY, OH 45840 (NAICS 000000). OSHA activity number 103062071.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DLM PLASTICS CORPORATION
- Site address
- 1530 HARVARD AVENUE
- City
- FINDLAY
- State
- OH
- ZIP
- 45840
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- Y
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 3089
- Employees
- 80
- Ownership type
- A
Citations
3 citations on file for this inspection.
5(a)(1)
- Issued
- Jun 20, 1989
- Abate by
- Dec 31, 1990
- Penalty
- Initial $1,000 · Current $600 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: Average readings of 132 mw/cm2 at the side of their heads on the #4 Thermation press for a period of .1 hour which is 124 times the standard. The Collocen #1 press averaged 80 mw/cm2 on the side of employees head for a 1 hour period which is 75 times the standard. The #3 Thermotion press readings averaged 21 mw/cm2 which is 20 times the standard. The corner thermation press averaged 26 mw/cm2 which is 24 times the standard. These values are over the recommended guidelines of the ACGIH 1988-1989 Radio-frequency/Microwave Radiation Threshold Limit Values. Abatement should consist of shielding the electrodes on the machines. Feasible methods of abatement include, but are not limited to the following: 1) Electrode shielding.
Recent events (3)
- · P (S) $600.00
- · I (S) $600.00
- · Z (S) $1000.00
1910.1025 D02
- Issued
- Feb 21, 1989
- Abate by
- Mar 24, 1989
1910.1025 L02 I
- Issued
- Feb 21, 1989
- Abate by
- Mar 3, 1989
More inspections at DLM Plastics Corporation
View DLM Plastics Corporation's full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 103062071.