VERNON HILLS, IL —
OSHA Inspection: ARETECH, INC.
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of ARETECH, INC. in 279 EVERGREEN DRIVE - EVERGREEN PLAZA, VERNON HILLS, IL 60061 (NAICS 000000). OSHA activity number 103072468.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ARETECH, INC.
- Site address
- 279 EVERGREEN DRIVE - EVERGREEN PLAZA
- City
- VERNON HILLS
- State
- IL
- ZIP
- 60061
- Mailing
- 1580 WEBSTER LANE, DES PLAINES, IL 60018
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 1542
- Employees
- 1
- Ownership type
- A
- Industry flags
- Construction safety.
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Dec 5, 1991
- Abate by
- Dec 8, 1991
- Penalty
- Initial $750 · Current $375 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and health Act of 1970: The %% employer id dnot furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: (a) On June 21 and 24, 1991, workers were exposed to the hazard of a building collapse involving roof trusses which had been or were in the process of being erected at the Evergreen Plaza jobsite in Vernon Hills, Illinois. Although some temporary bracing was installed during and after the truss erection, it was inadequate. The temporary bracing was insufficient as to their number, spacing, lapping, nailing, and time of placement. Abatement of this hazard could have been achieved by the in- stallation of a temporary bracing syustem which met or exceeded the recommendations of the truss plate institute, Inc. of Madison, Wisconsin as published in their document entitled, "Commentary and Recommendations for handling, installing and bracing metal connected wood trusses".
Recent events (2)
- — F (S) $375.00
- — Z (S) $750.00