JANESVILLE, WI —
OSHA Inspection: ACCUDYNE CORPORATION
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of ACCUDYNE CORPORATION in 101 ROCKPORT RD., JANESVILLE, WI 53547 (NAICS 000000). OSHA activity number 103142931.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ACCUDYNE CORPORATION
- Site address
- 101 ROCKPORT RD.
- City
- JANESVILLE
- State
- WI
- ZIP
- 53547
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 3483
- Employees
- 195
- Ownership type
- A
- Industry flags
- Manufacturing safety.
Citations
10 citations on file for this inspection.
5(a)(1)
- Issued
- May 23, 1989
- Abate by
- Jun 30, 1989
- Penalty
- Initial $600 · Current $300 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: Machine operators, engineering technicians and maintenance workers not protected from exposure to unaticipated machine movement. Among other methods, one feasible nd acceptable abatement method to correct these hazards is to establish and enforce an adequate lockout/ tagout of energy sources in accordance with ANSI Z244.1-1-1982, "American National Standard for Personnel Protection - Lockout/Tagout of Energy Sources-Minimum Safety Requirements". Essential elements of this lockout/tagout procedure would include: 1) Require lockout before any maintenance, inspection, clearing, adjusting or servicing that requires employees to enter or be in close contact with moving machinery or equipment. 2) Require that each exposed employee lockout the energy isolating device with his/her personal lock. 3) Maintain available operation and maintenance manuals on all machinery or equipment to be serviced. Assure that these manuals and other appropriate are provided to employees before work is begun. 4) Establish and use a documented work order system for machinery maintenance and repairs which includes Supervisors' approval to reactivate machinery or equipment after servicing. 5) Disconnect or isolate machinery or equipment by positioning the switch, valve or other energy isolating device so that energy sources (e.g. electrical, mechanical, hydraulic, etc.) are deactivated. Stored energy such as that in capacitors, springs, relevated machine members, rotating flywheels, hydraulic systems, and gas, air, steam or water pressure, etc., must be dissipated or restrained by methods such as grounding, repositioning, blocking, bleeding down, etc. 6) Test machinery or equipment to ensure that the energy sources have been effectively disconnected or isolated. As a precautionary measure return the operating controls to the "Off" position after the test has been completed. NOTE: The test shall only be performed after ensuring that no employees are exposed in the machine or equipment area. 7) Remove locks only after ensuring the safety of all exposed employees. 8) Train employees responsible for machinery or equipment lockout in all elements of the program. This training shall be repeated as frequently as necessary to maintain management and work proficiency, and compliance with the procedure. 9) Evaluate the program periodically to ensure continued use and adequacy. 10) Enforce all provisions of the program.
Recent events (2)
- — I (S) $300.00
- — Z (S) $600.00
1910.38 A01
- Issued
- May 23, 1989
- Abate by
- Jun 30, 1989
- Penalty
- Initial $500 · Current $250 Reduced
Recent events (2)
- — I (S) $250.00
- — Z (S) $500.00
1910.157 G03
- Issued
- May 23, 1989
- Abate by
- Jun 30, 1989
Recent events (2)
- — I (S)
- — Z (S)
1910.1200 H01
- Issued
- May 23, 1989
- Abate by
- Jul 15, 1989
- Penalty
- Initial $700 · Current $350 Reduced
Recent events (2)
- — I (S) $350.00
- — Z (S) $700.00
1910.132 A
- Issued
- May 23, 1989
- Abate by
- Jun 30, 1989
- Penalty
- Initial $7,000 · Current $900 Reduced
Recent events (2)
- — I (S) $900.00
- — Z (W) $7000.00
1910.20 G01 I
- Issued
- May 23, 1989
- Abate by
- May 31, 1989
Recent events (2)
- — I (O)
- — Z (O)
1910.20 G01 II
- Issued
- May 23, 1989
- Abate by
- May 31, 1989
Recent events (2)
- — I (O)
- — Z (O)
1910.20 G01 III
- Issued
- May 23, 1989
- Abate by
- May 31, 1989
Recent events (2)
- — I (O)
- — Z (O)
1910.20 G02
- Issued
- May 23, 1989
- Abate by
- May 31, 1989
Recent events (2)
- — I (O)
- — Z (O)
1910.95 C01
- Issued
- May 23, 1989
- Abate by
- Jul 15, 1989
Recent events (2)
- — I (O)
- — Z (O)
More inspections at Accudyne Corporation
View Accudyne Corporation's full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in WI
Source