WEST CHICAGO, IL ·
OSHA Inspection: FOAMTEK
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of FOAMTEK in 1151 ATLANTIC, UNIT 5, WEST CHICAGO, IL 60185 (NAICS 000000). OSHA activity number 103199048.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FOAMTEK
- Site address
- 1151 ATLANTIC, UNIT 5
- City
- WEST CHICAGO
- State
- IL
- ZIP
- 60185
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 3086
- Employees
- 6
- Ownership type
- A
Citations
10 citations on file for this inspection.
5(a)(1)
- Issued
- Jun 27, 1990
- Abate by
- Dec 27, 1990
- Penalty
- Initial $200 · Current $200
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of mucous membrane irritation, tightness in the chest, respiratory tract irritation, shortness of breath and/or sensitization resulting in asthma-like symptoms caused by the inhalationof methylene bisphenyl isocvanate (MDI) vented into the plant atmosphere from the two (2) MDI bulk storage tanks and mixer A. Among other methods, one feasible and acceptable abatement method to correct this hazard include, but are not necessarily limited to, the following: 1) For tanks situated inside the building, outlet of relief valve must be piped to a safe location away from personnel. 2) Vent all pipes, for tanks situated inside the building, to the outside.
1910.120 Q01
- Issued
- Jun 27, 1990
- Abate by
- Dec 27, 1990
- Penalty
- Initial $200 · Current $200
1910.120 Q03 IV
- Issued
- Jun 27, 1990
- Abate by
- Sep 27, 1990
- Penalty
- Initial $200 · Current $200
1910.120 Q06
- Issued
- Jun 27, 1990
- Abate by
- Dec 27, 1990
- Penalty
- Initial $200 · Current $200
1910.151 C
- Issued
- Jun 27, 1990
- Abate by
- Jul 30, 1990
- Penalty
- Initial $200 · Current $200
1910.212 A01
- Issued
- Jun 27, 1990
- Abate by
- Jul 30, 1990
- Penalty
- Initial $160 · Current $160
1910.219 E03 I
- Issued
- Jun 27, 1990
- Abate by
- Jul 30, 1990
- Penalty
- Initial $160 · Current $160
1910.1200 G02 I
- Issued
- Jun 27, 1990
- Abate by
- Dec 27, 1990
- Penalty
- Initial $200 · Current $200
1910.1200 G02 IC1
- Issued
- Jun 27, 1990
- Abate by
- Dec 27, 1990
1910.1200 G02 VI
- Issued
- Jun 27, 1990
- Abate by
- Dec 27, 1990
More inspections in this industry (NAICS 000000)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 103199048.