ROCKTON, IL ·
OSHA Inspection: BELOIT CORPORATION, R & D CENTER
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of BELOIT CORPORATION, R & D CENTER in 1165 PRAIRIE HILL RD., ROCKTON, IL 61072 (NAICS 000000). OSHA activity number 103201026.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BELOIT CORPORATION, R & D CENTER
- Site address
- 1165 PRAIRIE HILL RD.
- City
- ROCKTON
- State
- IL
- ZIP
- 61072
- Mailing
- 1 ST. LAWRENCE AVE., BELOIT, WI 53511
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Union (Y)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 3554
- Employees
- 400
- Ownership type
- Private (A)
- Industry flags
- Manufacturing safety.
Citations
2 citations on file for this inspection.
1910.67 C02 V
- Issued
- Nov 27, 1989
- Abate by
- Nov 30, 1989
- Penalty
- Initial $540 · Current $540
5(a)(1)
- Issued
- Nov 27, 1989
- Abate by
- Dec 11, 1989
- Penalty
- Initial $9,000 · Current $4,500 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to an unsafe atmosphere in which to work: On or about August 29, 1989, the employer knowingly and intentionally allowed an untrained mechanic to enter Headbox No. B5479 to pneumatically grind the seams on the stainless steel transition piece. The employee was working in a 25 inch diameter opening approximately 16 feet long. The Corporations' established Confined Space Entry Procedure was not implemented to ensure that the employee was provided with a safe atmosphere to work within. Among other methods, one feasible and acceptable abatement method to correct this hazard is to establish enforce an adequate plant Confined Space Entry Program such as that stipulated by ANSI Z117.1-1977, Safety Requirements for Working in Tanks and Other Confined Spaces. Such a program shall include, as a minimum, the following elements: 1) Written procedures covering a permit system, ventilations, atmospheric testing, rescue procedures, and employee training. 2) The completion and posting of a warnig sign and a confined space entry permit which requires authorization and approval in writing that specifies the location and type of work to be done and certifies that all existing and potential hazards have been evaluated by a qualified person designated by the employer, and necessary protective measures have been taken to ensure the safety of each worker. 3) Mechanical ventilation of the confined space prior to entry and continued ventilation to provide a safe atmosphere, when determined necessary as described in (2) above. 4) Testing the atmosphere of the confined space prior to entry and on a regular basis for presence of sufficient oxygen (19.5% to 25%) and absence of hazardous levels of toxic or combustible gases or vapors, when determined necessary as described in (2) above. 5) Emergency rescue procedures with a requirement that trained personnel are available and are stationed outside the confined space with proper equipment to provide for the rescue of persons entering the space as determined necessary as described in (2) above. Such equipment must include safety harness and life lines with provisions for hoisting employees from the confined space. If entry is required for rescue, the rescuing employee must be equipped with approved air supplied respiratory equipment and other appropriate personal protective equipment. NOTE: Under no circumstances is the standby person to enter the confined space until assured that adequate assistance is present. 6) Training of any and all employees required to enter the confined spaces. This training shall include procedures required prior to entry and hazards associated with work in confined spaces.
Recent events (2)
- · F (R) $4500.00
- · Z (W) $9000.00
More inspections at Beloit Corporation, R & D Center
View Beloit Corporation, R & D Center's full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 103201026.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.