OSHA Inspection: FRANK KETTMAN DBA KETTMAN HEATING REFRIG. & AIR

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of FRANK KETTMAN DBA KETTMAN HEATING REFRIG. & AIR in 820 BRUNNER STREET, PERU, IL 61354 (NAICS 000000). OSHA activity number 103201703.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Frank Kettman DBA Kettman Heating Refrig. & AIR — free Get an email when a new federal OSHA severe-injury report for Frank Kettman DBA Kettman Heating Refrig. & AIR is published. One employer, no account, unsubscribe in one click.
Site address
820 BRUNNER STREET
City
PERU
State
IL
ZIP
61354
Mailing
413 S. ELM, BOX 223, GRANVILLE, IL 61326
Inspection type
Unprogrammed Related (G)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Data loaded
NAICS code
000000
SIC code (legacy)
1711
Employees
10
Ownership type
A
Industry flags
Construction safety.

6 citations on file for this inspection.

5(a)(1)

Serious Gravity 07 1 instance 1 exposed
Issued
Sep 14, 1989
Abate by
Sep 29, 1989
Penalty
Initial $210 · Current $210
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
%%
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to
the hazard of electrocution when installation or repairing machinery or
equipment such as the Arrow Refrigerated Air Dryer SN11418.
In the establishement, the employer did not provide an adequate program,
nor were employees adequately trained in the recognition of hazards,
safe shut down of machines and reducing machines to zero mechanical
state as evident by the operation of replacing a compressor on the
Arrow Dryer SN11418 without locking out the electrical power source.
Among other methods, one feasible and acceptable method to correct
these hazards is to establish administrative controls and procedures
over the work being performed which will instruct workers in the
recognition of these hazards; ensure safe shutdown of machinery and
equipment by blocking, stopping or otherwise reducing to a zero
mechanical state.
Specific elements of the abatement program shall be expected to include,
but not necessarily be limited to:
1) Establish a comprehensive written procedure for lock-out which
includes procedures designed to instruct and train employees in
recognition of hazards and proper lock-out procedures.
2) Require lock-out before any maintenance, inspection, clearing,
adjusting or servicing that requires employees to enter or be in
close contact with machinery or equipment.
3) Maintain available operation and maintenance manuals on all machinery
or equipment. Assure that these manuals and other appropriate
information are provided to employees before work is begun.
4) Establish and use a documented work order system which includes
Supervisors' approval to reactivate machinery or equipment.
5) Disconnect or isolate machinery or equipment by positioning the
switch, valve or other energy isolating device so that all energy
sources (e.g. electrical, mechanical, hydraulic, etc.,) are
deactivated. Stored energy such as that in capacitors, springs,
elevated machine members, rotating flywheels, hydraulic systems and
gas, air, steam or water pressure, etc., must be dissipated or
restrained by methods such as grounding, repositioning, blocking,
bleeding, etc.
6) Require that each exposed employee lock-out the energy isolating
device with his/her personal lock.
7) Test machinery or equipment to ensure that the energy sources have
been effectively disconnected or isolated. As a precautionarymeasure
return the operating controls to the "OFF" position after the test
has been completed. NOTE: The test shall only be performed after
ensuring that no employees are exposed in the machine or equipment
area.
8) Remove locks only after ensuring the safety or all exposed
employees.
9) Train employees responsible for machinery or equipment lock-out in
all elements of the program. This training shall be repeated as
frequently as necessary to maintain management and work proficiency
and compliance with the procedure.
10) Evaluate the program periodically to ensure continued use and
adequacy.
11) Enforce all provisions of the program.

1926.404 B01 II

Serious Gravity 04 1 instance 1 exposed
Issued
Sep 14, 1989
Abate by
Sep 29, 1989
Penalty
Initial $120 · Current $120
Recent events (2)
  • — I (S) $120.00
  • — Z (S) $120.00

1926.404 F06

Serious Gravity 04 1 instance 1 exposed
Issued
Sep 14, 1989
Abate by
Sep 19, 1989

1926.59 E01

Other-than-serious Gravity 01 1 instance 1 exposed
Issued
Sep 14, 1989
Abate by
Oct 30, 1989
Recent events (2)
  • — I (O)
  • — Z (O)

1926.59 G01

Other-than-serious Gravity 01 1 instance 1 exposed
Issued
Sep 14, 1989
Abate by
Oct 30, 1989
Recent events (2)
  • — I (O)
  • — Z (O)

1926.59 H

Other-than-serious Gravity 01 1 instance 1 exposed
Issued
Sep 14, 1989
Abate by
Oct 30, 1989
Recent events (2)
  • — I (O)
  • — Z (O)

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 103201703.