PERU, IL —
OSHA Inspection: FRANK KETTMAN DBA KETTMAN HEATING REFRIG. & AIR
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of FRANK KETTMAN DBA KETTMAN HEATING REFRIG. & AIR in 820 BRUNNER STREET, PERU, IL 61354 (NAICS 000000). OSHA activity number 103201703.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FRANK KETTMAN DBA KETTMAN HEATING REFRIG. & AIR
- Site address
- 820 BRUNNER STREET
- City
- PERU
- State
- IL
- ZIP
- 61354
- Mailing
- 413 S. ELM, BOX 223, GRANVILLE, IL 61326
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 1711
- Employees
- 10
- Ownership type
- A
- Industry flags
- Construction safety.
Citations
6 citations on file for this inspection.
5(a)(1)
- Issued
- Sep 14, 1989
- Abate by
- Sep 29, 1989
- Penalty
- Initial $210 · Current $210
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The %% employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of electrocution when installation or repairing machinery or equipment such as the Arrow Refrigerated Air Dryer SN11418. In the establishement, the employer did not provide an adequate program, nor were employees adequately trained in the recognition of hazards, safe shut down of machines and reducing machines to zero mechanical state as evident by the operation of replacing a compressor on the Arrow Dryer SN11418 without locking out the electrical power source. Among other methods, one feasible and acceptable method to correct these hazards is to establish administrative controls and procedures over the work being performed which will instruct workers in the recognition of these hazards; ensure safe shutdown of machinery and equipment by blocking, stopping or otherwise reducing to a zero mechanical state. Specific elements of the abatement program shall be expected to include, but not necessarily be limited to: 1) Establish a comprehensive written procedure for lock-out which includes procedures designed to instruct and train employees in recognition of hazards and proper lock-out procedures. 2) Require lock-out before any maintenance, inspection, clearing, adjusting or servicing that requires employees to enter or be in close contact with machinery or equipment. 3) Maintain available operation and maintenance manuals on all machinery or equipment. Assure that these manuals and other appropriate information are provided to employees before work is begun. 4) Establish and use a documented work order system which includes Supervisors' approval to reactivate machinery or equipment. 5) Disconnect or isolate machinery or equipment by positioning the switch, valve or other energy isolating device so that all energy sources (e.g. electrical, mechanical, hydraulic, etc.,) are deactivated. Stored energy such as that in capacitors, springs, elevated machine members, rotating flywheels, hydraulic systems and gas, air, steam or water pressure, etc., must be dissipated or restrained by methods such as grounding, repositioning, blocking, bleeding, etc. 6) Require that each exposed employee lock-out the energy isolating device with his/her personal lock. 7) Test machinery or equipment to ensure that the energy sources have been effectively disconnected or isolated. As a precautionarymeasure return the operating controls to the "OFF" position after the test has been completed. NOTE: The test shall only be performed after ensuring that no employees are exposed in the machine or equipment area. 8) Remove locks only after ensuring the safety or all exposed employees. 9) Train employees responsible for machinery or equipment lock-out in all elements of the program. This training shall be repeated as frequently as necessary to maintain management and work proficiency and compliance with the procedure. 10) Evaluate the program periodically to ensure continued use and adequacy. 11) Enforce all provisions of the program.
1926.404 B01 II
- Issued
- Sep 14, 1989
- Abate by
- Sep 29, 1989
- Penalty
- Initial $120 · Current $120
Recent events (2)
- — I (S) $120.00
- — Z (S) $120.00
1926.404 F06
- Issued
- Sep 14, 1989
- Abate by
- Sep 19, 1989
1926.59 E01
- Issued
- Sep 14, 1989
- Abate by
- Oct 30, 1989
Recent events (2)
- — I (O)
- — Z (O)
1926.59 G01
- Issued
- Sep 14, 1989
- Abate by
- Oct 30, 1989
Recent events (2)
- — I (O)
- — Z (O)
1926.59 H
- Issued
- Sep 14, 1989
- Abate by
- Oct 30, 1989