BURLINGTON, WI —
OSHA Inspection: FOSTER FORBES GLASS CO. DIV. OF NAT'L CAN CORP.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of FOSTER FORBES GLASS CO. DIV. OF NAT'L CAN CORP. in 815 SOUTH MCHENRY STREET, BURLINGTON, WI 53105 (NAICS 000000). OSHA activity number 103309076.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FOSTER FORBES GLASS CO. DIV. OF NAT'L CAN CORP.
- Site address
- 815 SOUTH MCHENRY STREET
- City
- BURLINGTON
- State
- WI
- ZIP
- 53105
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Y
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 3221
- Employees
- 385
- Ownership type
- A
- Industry flags
- Manufacturing safety.
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Mar 15, 1990
- Abate by
- Mar 19, 1990
- Penalty
- Initial $900 · Current $455 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: a) The increased likelihood of fires and/or explosions from the use of unapproved, shop made natural gas-fired area heating appliances constructed from 55-gallon drums located in the basement furnace and batch area hot end. Among other methods, one feasible and acceptable abatement method to correct this hazard is to install natural gas piping and heating appliances in accordance with the provisions stipulated in the National Fuel Gas Code, ANSI Z233.1-1988 (NFPA 54-1988). Specific elements of abatement shall include, but not necessarily be limited to, the following: 1) Gas piping shall be designed, sized installed in inspected in accordance with parts 2-4 of the above referenced ANSI standard. 2) Heating appliances shall be installed, vented and operated in accordance with parts 5-8 of the above referenced ANSI standard.
Recent events (2)
- — I (S) $455.00
- — Z (S) $900.00
More inspections at Foster Forbes Glass CO. DIV. of Nat'L CAN Corp.
View Foster Forbes Glass CO. DIV. of Nat'L CAN Corp.'s full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 103309076.