Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,201Inspections Most recent open 2026-08-31 Last loaded 2026-09-03

OSHA Inspection: COOPER POWER SYSTEMS INC.

Accident-driven inspection · Safety discipline

On , OSHA opened an accident-driven safety inspection of COOPER POWER SYSTEMS INC. in 1319 E. LINCOLN AVE., WAUKESHA, WI 53186 (NAICS 000000). OSHA activity number 103313953.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Cooper Power Systems INC. for free Get an email when a new federal OSHA severe-injury report for Cooper Power Systems INC. is published. One employer, no account, unsubscribe in one click.
Site address
1319 E. LINCOLN AVE.
City
WAUKESHA
State
WI
ZIP
53186
Inspection type
Accident-driven (A)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (N)
Opened
Closing conference
Case closed
Data loaded
NAICS code
000000
SIC code (legacy)
3612
Employees
382
Ownership type
Private (A)
Industry flags
Manufacturing safety.

1 citation on file for this inspection.

5(a)(1)

Serious Gravity 08 1 instance 3 exposed
Issued
Sep 28, 1989
Abate by
Oct 1, 1989
Penalty
Initial $640 · Current $640
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
a) Finish painters were subject to the hazards of being struck by or
crushed by transformers being unintentionally discahrged off the open
ends of the conveyor on which they are being painted. This conveyor
is located in the finish paint booth and designated conveyor G.
Feasible and acceptable methods of abatement to correct this hazard is
to establish and enforce procedures such as those stipulated by American
National Standard B20.1-1984 Safety Standards for Conveyors and Related
Equipment paragraphs 5.11.3 and 5.12. Essential elements would include
but not be limited to:
a) Only trained employees shall be permitted to operate conveyors.
Training shall include instructions in operation under normal
conditions and emergency situations.
b) Personnel working on or near a conveyor shall be instructed as to the
location and operation of pertinent stopping devices.
c) Routine inspections and preventive and corrective maintenance
programs shall be conducted to insure that all safety features and
devices are retained and function properly.
d) All safety devices shall be arranged to operate in a "fail safe"
manner. That is if power failure or failure to the device itself
would occur, a hazardous condition must not result.

View Cooper Power Systems INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 103313953.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.