OSHA Inspection: PULLMAN POWER PRODUCTS CORPORATION

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of PULLMAN POWER PRODUCTS CORPORATION in 7397 STATE ROUTE 7 NORTH, CHESHIRE, OH 45620 (NAICS 000000). OSHA activity number 103336384.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Pullman Power Products Corporation — free Get an email when a new federal OSHA severe-injury report for Pullman Power Products Corporation is published. One employer, no account, unsubscribe in one click.
Site address
7397 STATE ROUTE 7 NORTH
City
CHESHIRE
State
OH
ZIP
45620
Mailing
P.O. BOX 378, CHESHIRE, OH 45620
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Y
Opened
Closing conference
Case closed
Data loaded
NAICS code
000000
SIC code (legacy)
1711
Employees
50
Ownership type
A

2 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 4 exposed
Issued
Mar 23, 1995
Abate by
Mar 28, 1995
Penalty
Initial $4,500 · Current $3,150 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:
The employer did not furnish employment and a place of employment
which were free from recognized hazards that were causing or likely
to cause death or serious physical harm to employees in that
employees were exposed to:
On 12/19/94, at the flyash common silo, the knife gate valve
located in the piping system (which contained over 200 tons of
flyash) was not closed and locked or tagged out prior to employees
removing an expansion flange located downstream of this valve.
A feasible method of abatement that could be used to correct this
hazard is:
In the piping system, lockout or tagout the knife gate
valve in the closed position to prevent premature or
accidental opening of the valve.g
Recent events (2)
  • — I (S) $3150.00
  • — Z (S) $4500.00

1926.59 H

Deleted Serious Gravity 10 1 instance 4 exposed
Issued
Mar 23, 1995
Abate by
Apr 25, 1995
Penalty
Initial $4,500 · Current $4,500
Recent events (2)
  • — I (S) $4500.00
  • — Z (S) $4500.00