BRECKSVILLE, OH —
OSHA Inspection: WILLARD CONSTRUCTION CO.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of WILLARD CONSTRUCTION CO. in 6500 MILL ROAD, BRECKSVILLE, OH 44141 (NAICS 000000). OSHA activity number 103537148.
Where did this inspection happen?
- Establishment
- WILLARD CONSTRUCTION CO.
- Site address
- 6500 MILL ROAD
- City
- BRECKSVILLE
- State
- OH
- ZIP
- 44141
- Mailing
- 10418 MEECH STREET, CLEVELAND, OH 44105
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Y
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 1623
- Employees
- 20
- Ownership type
- A
Citations
6 citations on file for this inspection.
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $1000.00 · Current $1000.00
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: An employee was exposed to an atmosphere immediately dangerous to life when he entered the confined space of the storm manhole in the driveway at 6575 Mill Road, Brecksville, Ohio, at a depth of about 10 feet. The employee was exposed to the potential hazards of an oxygen deficient atmosphere and/or toxic/combustible gases and vapors. The employer failed to implement a confined space entry program which would assure work performed within the confined space area could be accomplished safely. A feasible method of abatement includes, but is not limited to: 1. Written procedures covering a permit system, ventilation, atmospheric testing, rescue procedures, and employee training. 2. The completion and posting of a confined space entry permit which requires authorization and approval in writing that specifies the location and type of work to be done and certifies that all existing and potential hazards have been evaluated by a qualified person and necessary protective measures have been taken to ensure the safety of each worker. 3. Mechanical ventilation of the confined space prior to entry and continued ventilation to provide a safe atmosphere, when determined necessary as described in #2 above. 4. Testing the atmosphere of the confined space prior to entry and on a regular basis for presence of sufficient oxygen (19.5) and absence of hazardous levels of toxic or combustible gases or vapors, when determined necessary as described in #2 above. 5. Emergency rescue procedures with a requirement that trained personnel are available and are stationed outside the confined space with proper equipment to provide for the rescue of persons entering the space as determined necessary as described in #2 above. Such equipment must include safety harness and lifelines with provisions for hoisting employees from the confined space. If entry is required for rescue, the rescuing employee must be equipped with approved air supplied respiratory equipment and other appropriate personal protective equipment. 6. Training of any and all employees required to enter the confined spaces. This training shall include procedures required prior to entry and the hazards associated with work in confined spaces.
Recent events (2)
- — I (S) $1000.00
- — Z (S) $1000.00
1926.21 B06 I
- Issued
- Abate by
- Penalty
- Initial $1000.00 · Current $1000.00
Recent events (2)
- — I (S) $1000.00
- — Z (S) $1000.00
1926.59 H01 III
- Issued
- Abate by
- Penalty
- Initial $800.00 · Current $480.00 Reduced
Recent events (2)
- — I (S) $480.00
- — Z (S) $800.00
1926.201 A04
- Issued
- Abate by
- Penalty
- Initial $1000.00 · Current $600.00 Reduced
Recent events (2)
- — I (S) $600.00
- — Z (S) $1000.00
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $600.00 · Current $600.00
1926.21 B06 I
- Issued
- Abate by
More inspections at WILLARD CONSTRUCTION CO.
OLMSTED FALLS, OH—1996-10-25 00:00:00
WILLARD CONSTRUCTION CO.
OLMSTED FALLS, OH—1996-07-24 00:00:00
WILLARD CONSTRUCTION CO.
CLEVELAND, OH—1992-12-15 00:00:00
WILLARD CONSTRUCTION CO.
GRANITE FALLS, WA—1992-04-01 00:00:00
WILLARD CONSTRUCTION CO
WARREN, OH—1991-09-11 00:00:00
WILLARD CONSTRUCTION CO.
View WILLARD CONSTRUCTION CO.'s full OSHA safety record →
More inspections in this industry (NAICS 000000)
SCHENECTADY, NY—2012-01-05 00:00:00
BRUCE D. BOWMAN
BILLINGS, MT—2005-01-25 00:00:00
KGC, INC.
ROCKAWAY, NJ—2002-12-31 00:00:00
ROCKAWAY BOROUGH DPW
FOREST CITY, NC—2002-12-31 00:00:00
HARRY BRICKEY DBA A. BRICKEY CEILING COMPANY
EDGERTON, KS—2002-12-31 00:00:00
SUDDEN BOND INDUSTRIES
More inspections in OH
WELLINGTON, OH—2026-07-16
WHIRLAWAY CORPORATION
WAUSEON, OH—2026-07-16
WATSON WELL DRILLING INC.
SEVEN HILLS, OH—2026-07-15
STONEY ACRES BUILDERS LLC
SEVEN HILLS, OH—2026-07-15
GRB ENTERPRISES LLC
CHILLICOTHE, OH—2026-07-15
KENWORTH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 103537148.