OSHA Inspection: CONTROLLED POWER CORP.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of CONTROLLED POWER CORP. in 1501 RAFF ROAD, S.W., CANTON, OH 44710 (NAICS 000000). OSHA activity number 103543252.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Controlled Power Corp. — free Get an email when a new federal OSHA severe-injury report for Controlled Power Corp. is published. One employer, no account, unsubscribe in one click.
Site address
1501 RAFF ROAD, S.W.
City
CANTON
State
OH
ZIP
44710
Mailing
P O BOX 80777, CANTON, OH 44710
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Y
Opened
Closing conference
Case closed
Data loaded
NAICS code
000000
SIC code (legacy)
3613
Employees
180
Ownership type
A
Industry flags
Manufacturing safety.

6 citations on file for this inspection.

1910.106 E02 IIB2

Serious Gravity 03 1 instance 10 exposed
Issued
Apr 7, 1995
Abate by
Apr 24, 1995
Penalty
Initial $1,625 · Current $893 Reduced
Recent events (2)
  • — I (S) $893.00
  • — Z (S) $1625.00

1910.106 E02 IVA

Serious Gravity 01 1 instance 10 exposed
Issued
Apr 7, 1995
Abate by
Apr 12, 1995
Penalty
Initial $975 · Current $536 Reduced
Recent events (2)
  • — I (S) $536.00
  • — Z (S) $975.00

1910.106 E09 III

Serious Gravity 01 1 instance 10 exposed
Issued
Apr 7, 1995
Abate by
Apr 12, 1995
Recent events (2)
  • — I (S)
  • — Z (S)

1910.107 E02

Serious Gravity 02 1 instance 10 exposed
Issued
Apr 7, 1995
Abate by
Apr 12, 1995
Penalty
Initial $1,300 · Current $715 Reduced
Recent events (2)
  • — I (S) $715.00
  • — Z (S) $1300.00

1910.107 G01

Serious Gravity 02 1 instance 3 exposed
Issued
Apr 7, 1995
Abate by
Apr 12, 1995
Penalty
Initial $1,300
Recent events (2)
  • — I (S)
  • — Z (S) $1300.00

1910.110 F02 I

Serious Gravity 01 1 instance 10 exposed
Issued
Apr 7, 1995
Abate by
Apr 12, 1995
Penalty
Initial $975 · Current $536 Reduced
Recent events (2)
  • — I (S) $536.00
  • — Z (S) $975.00

View Controlled Power Corp.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 103543252.