Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BONAR PACKAGING, INC.

Follow-up inspection · Health discipline

On , OSHA opened a follow-up health inspection of BONAR PACKAGING, INC. in 2410 N. LYNDON STREET, TYLER, TX 75710 (NAICS 000000). OSHA activity number 103564910.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Bonar Packaging, INC. — free Get an email when a new federal OSHA severe-injury report for Bonar Packaging, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2410 N. LYNDON STREET
City
TYLER
State
TX
ZIP
75710
Mailing
P. O. BOX 818, TYLER, TX 75710
Inspection type
Follow-up (F)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
Y
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
000000
SIC code (legacy)
2671
Employees
240
Ownership type
A

1 citation on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 20 exposed
Issued
Feb 10, 1994
Abate by
Mar 30, 1994
Penalty
Initial $5,000 · Current $3,750 Reduced
SECTION 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to:
Employees working in and near the printing press operation were exposed
to the recognized
potential hazard of fire and explosion at the Number 1 (Turner) fume
incineration unit.  The
employer did not take adequate measures to ensure flammable vapors would
remain controlled
below the recognized safety limit of 25of the lower explosive limit
(LEL) for those vapors,
in that:
a.Ventilation essential to the safe operation of the unit was not proven
and
interlocked with the fuel supply to the burner;
b.Adequate air volume for the entire range of vapor volumes specified for
fume
incineration unit was not assured;
c.Fuel supply shutoff valve(s) were located in close proximity to the fume
incineration unit at issue, precluding their use in emergency situations.
Among other methods, feasible and acceptable means of abatement ot
correct this hazard
include:
1.Knowledgable assessment of the number 1 fume incinerator regarding the
safe
design and operation of these units as outlined in National Fire
Protection Association (NFPA)
standard 86 (Ovens and Furnaces, 1990 Edition), with particular attention
to section 45 on
proven air flow interlocks and section 43 on preignition requirements for
equipment;
2.Installation of equipment modifications such that the number 1 fume
incinerator
can operate without deviation from NFPA satndard 86;
3.Documentation of the final design and operating parameters so that the
equipment
can be maintained and operated in accordance with NFPA standard 86.
Training on this
documentation for all employees required to work with the fume
incineration units is necessary
for the safe opertion of the incinerators.
Recent events (2)
  • — F (S) $3750.00
  • — Z (S) $5000.00

View Bonar Packaging, INC.'s full OSHA safety record →