CALLIHAM, TX ·
OSHA Inspection: GREENE'S PRESSURE TESTING & RENTALS, INC.
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of GREENE'S PRESSURE TESTING & RENTALS, INC. in HWY 59 & FM 624, 25 MILES SOUTH, CALLIHAM, TX 78007 (NAICS 000000). OSHA activity number 103582011.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GREENE'S PRESSURE TESTING & RENTALS, INC.
- Site address
- HWY 59 & FM 624, 25 MILES SOUTH
- City
- CALLIHAM
- State
- TX
- ZIP
- 78007
- Mailing
- P. O. BOX 80129, LAFAYETTE, LA 70598
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 1389
- Employees
- 1
- Ownership type
- A
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- May 18, 1995
- Abate by
- May 22, 1995
- Penalty
- Initial $2,500 · Current $1,250 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to hazards of being struck by pressurized equipment: Employees were exposed to the hazards of being struck by pressurized equipment (ball valve & connections) which was inadequately sized and had been subjected to pressure of approximately 2,500 p.s.i. One feasible and acceptable abatement method, among others, to correct the hazards is to assure that all pipe fittings, valves, and unions placed on or connected with blowout prevention equipment, well casing, casinghead, drill pipe, or tubing and exposed to well pressure shall have a working pressure rating equal to or greater than the maximum anticipated well surface pressure as specified by API RP54 92, page 11, paragraph 5.4.3. This alleged condition occurred on or about January 6, 1995.ry