REFUGIO, TX —
OSHA Inspection: COBRA WELL SERVICE, RIG #5
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of COBRA WELL SERVICE, RIG #5 in FM 774, 5 MI E. OF REFUGIO, REFUGIO, TX 78377 (NAICS 000000). OSHA activity number 103584074.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- COBRA WELL SERVICE, RIG #5
- Site address
- FM 774, 5 MI E. OF REFUGIO
- City
- REFUGIO
- State
- TX
- ZIP
- 78377
- Mailing
- P.O. BOX 3782, VICTORIA, TX 77903
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 1389
- Employees
- 5
- Ownership type
- A
Citations
14 citations on file for this inspection.
5(a)(1)
- Issued
- Aug 12, 1994
- Abate by
- Aug 17, 1994
- Penalty
- Initial $1,500 · Current $900 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to fire and explosion: The hazard of being restricted in escape from the monkeyboard in the event of fire or explosion. This occurred on or about July 25, 1994 on Cobra Well Service Rig #5. Among other methods, one feasible and acceptable abatement method to correct this hazard would be installation of a properly rigged and secured emergency descent device or other satisfactory means of egress, such as, specified in Section 4.7, paragraph 4.7.1 of A.P.I. RP54 First Edition, January 1981, page 11. Essential elements of this would include: a. Staking out a securely anchored 1/2-inch wire rope escape line attached to the derrick or mast so as to provide a ready and convenient means of escape from the derrickman's working platform. b. The escape line route is to be kept clear of obstructions. c. A safety device is to be provided to permit fast emergency exit from the derrickman's working platform to a safe place. d. The tension on the escape line is to be periodically checked and adjusted to assure a safe landing and to allow the derrickman to stop 20 to 25 feet from the anchor point. e. The ground anchor point of the escape line is to be located a minimum lateral distance from the derrick or mast equal to the height above ground to the point where the escape line fastened to the derrick or mast.
Recent events (2)
- — I (S) $900.00
- — Z (S) $1500.00
5(a)(1)
- Issued
- Aug 12, 1994
- Abate by
- Aug 17, 1994
- Penalty
- Initial $1,500 · Current $500 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of being struck by a high pressure flow line: The hazard of being struck by a high pressure flow line coming from the mud pump that was not secured or staked out. This occurred on or about July 25, 1994, on Cobra Well Service Rig #5. Among other methods, one feasible and acceptable abatement method to correct this hazard is to secure the flow line to the ground as specified in paragraph 11.4.4 of API RP54 First Edition January 1981. Essential elements of this would include: a. Secure or anchor the flow line at the end of the flow line and at intermediate intervals along the line 15 to 20 feet. b. Where chic-san swivel connections are used to make a turn in a flow line, and shall be anchored to the ground by means of chains, steel stakes or other adequate restraint on both ends of the chic-san swivel connection. c. That employees shall not be permitted to step across and/or work on a pressurized proximity to the pressurized flow line.
Recent events (2)
- — I (S) $500.00
- — Z (S) $1500.00
1910.23 C01
- Issued
- Aug 12, 1994
- Abate by
- Aug 20, 1994
- Penalty
- Initial $450
Recent events (2)
- — I (S)
- — Z (S) $450.00
1910.23 D01 II
- Issued
- Aug 12, 1994
- Abate by
- Sep 25, 1994
- Penalty
- Initial $450 · Current $270 Reduced
Recent events (2)
- — I (S) $270.00
- — Z (S) $450.00
1910.27 B01 II
- Issued
- Aug 12, 1994
- Abate by
- Aug 20, 1994
- Penalty
- Initial $450 · Current $270 Reduced
Recent events (2)
- — I (S) $270.00
- — Z (S) $450.00
1910.27 D05
- Issued
- Aug 12, 1994
- Abate by
- Aug 16, 1994
- Penalty
- Initial $1,500 · Current $900 Reduced
Recent events (2)
- — I (S) $900.00
- — Z (S) $1500.00
1910.141 B01 VI
- Issued
- Aug 12, 1994
- Abate by
- Aug 16, 1994
- Penalty
- Initial $450 · Current $270 Reduced
Recent events (2)
- — I (S) $270.00
- — Z (S) $450.00
1910.151 B
- Issued
- Aug 12, 1994
- Abate by
- Aug 25, 1994
- Penalty
- Initial $450 · Current $270 Reduced
Recent events (2)
- — I (S) $270.00
- — Z (S) $450.00
1910.219 D01
- Issued
- Aug 12, 1994
- Abate by
- Aug 20, 1994
- Penalty
- Initial $450 · Current $270 Reduced
Recent events (2)
- — I (S) $270.00
- — Z (S) $450.00
1910.219 E03 I
- Issued
- Aug 12, 1994
- Abate by
- Aug 20, 1994
Recent events (2)
- — I (S)
- — Z (S)
1910.1200 E01
- Issued
- Aug 12, 1994
- Abate by
- Sep 25, 1994
- Penalty
- Initial $450
Recent events (2)
- — I (O)
- — Z (S) $450.00
1904.2 A
- Issued
- Aug 12, 1994
- Abate by
- Aug 20, 1994
- Penalty
- Initial $300 · Current $180 Reduced
Recent events (2)
- — I (O) $180.00
- — Z (O) $300.00
1910.157 C04
- Issued
- Aug 12, 1994
- Abate by
- Aug 17, 1994
Recent events (2)
- — I (O)
- — Z (O)
1910.1200 G01
- Issued
- Aug 12, 1994
- Abate by
- Aug 25, 1994
Recent events (2)
- — I (O)
- — Z (O)
More inspections in this industry (NAICS 000000)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 103584074.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.