OSHA Inspection: AUTOMATED BUILDING COMPONENTS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of AUTOMATED BUILDING COMPONENTS, INC. in 1111 8TH ST., CHETEK, WI 54728 (NAICS 000000). OSHA activity number 106051436.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Automated Building Components, INC. for free Get an email when a new federal OSHA severe-injury report for Automated Building Components, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1111 8TH ST.
City
CHETEK
State
WI
ZIP
54728
Mailing
PO BOX 133, CHETEK, WI 54728
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (N)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
000000
SIC code (legacy)
2439
Employees
135
Ownership type
Private (A)

12 citations on file for this inspection.

5(a)(1)

Serious Gravity 02 1 instance 135 exposed
Issued
Aug 17, 2001
Abate by
Aug 29, 2001
Penalty
Initial $1,300 · Current $910 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to the hazard of crushing injury or death when
entering/exiting through the
overhead door:
(a)Throughout plant; one or more of the overhead doors had disconnected
safety
devices and were equipped with 3 button switches that were not constant
pressure
switches.
Among other methods, three feasible and acceptable abatement methods to
correct this hazard
are:
(1)A constant pressure actuation switch.  This would always be operated in
sight of
the door so that it could be released and manually reversed before an
obstruction
was hit.
(2)Installation of a reversing edge switch.  This would allow an automatic
closing
control out of sight of the door, but would immediately reverse the
direction of
the door upon striking an obstruction.  A variation to this option would
be the use
of photoelectric cells that would reverse the door when an obstruction was
encountered by the beam.
(3)A three-button control switch.  If the following conditions are also
met:
a)It is provided with a permanent placard adjacent to the switch with the
following warning letters at least " high:
- WARNING -
- TO PREVENT ENTRAPMENT-
DO NOT START DOOR DOWNWARD
UNLESS DOORWAY IS CLEAR
b)The control station and placard are located within sight of the doorway.
c)Automatic closing controls are not also installed.
d)Operator must remain at the control station and observe the door until
the
door is fully closed.
Recent events (2)
  • · I (S) $910.00
  • · Z (S) $1300.00

1910.147 C04 I

Serious Gravity 02 1 instance 3 exposed
Issued
Aug 17, 2001
Abate by
Sep 20, 2001
Penalty
Initial $1,300 · Current $910 Reduced
Recent events (2)
  • · I (S) $910.00
  • · Z (S) $1300.00

1910.213 D01

Serious Gravity 03 1 instance 6 exposed
Issued
Aug 17, 2001
Abate by
Aug 29, 2001
Penalty
Initial $1,625 · Current $1,137 Reduced
Recent events (2)
  • · I (S) $1137.00
  • · Z (S) $1625.00

1910.213 R04

Serious Gravity 01 1 instance 1 exposed
Issued
Aug 17, 2001
Abate by
Sep 6, 2001

1910.253 B04 III

Serious Gravity 01 1 instance 1 exposed
Issued
Aug 17, 2001
Abate by
Aug 23, 2001
Penalty
Initial $975 · Current $683 Reduced
Recent events (2)
  • · I (S) $683.00
  • · Z (S) $975.00

1910.134 C02 I

Other-than-serious Gravity 01 1 instance 1 exposed
Issued
Aug 17, 2001
Abate by
Sep 6, 2001

1910.147 C07 I

Other-than-serious Gravity 01 1 instance 2 exposed
Issued
Aug 17, 2001
Abate by
Sep 20, 2001

1910.219 C04 I

Other-than-serious Gravity 01 1 instance 2 exposed
Issued
Aug 17, 2001
Abate by
Sep 6, 2001

1910.219 D01

Other-than-serious Gravity 01 2 instances 1 exposed
Issued
Aug 17, 2001
Abate by
Sep 6, 2001

1910.219 E01 I

Other-than-serious Gravity 01 1 instance 1 exposed
Issued
Aug 17, 2001
Abate by
Sep 6, 2001

1910.219 E03 I

Other-than-serious Gravity 01 1 instance 1 exposed
Issued
Aug 17, 2001
Abate by
Sep 6, 2001

1910.305 B01

Other-than-serious Gravity 01 1 instance 4 exposed
Issued
Aug 17, 2001
Abate by
Aug 29, 2001

View Automated Building Components, INC.'s full OSHA safety record →