Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MONDOVI IMPLEMENT CO. INC.

Accident-driven inspection · Safety discipline

On , OSHA opened an accident-driven safety inspection of MONDOVI IMPLEMENT CO. INC. in 994 E. MAIN ST., MONDOVI, WI 54755 (NAICS 000000). OSHA activity number 106053788.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Mondovi Implement CO. INC. — free Get an email when a new federal OSHA severe-injury report for Mondovi Implement CO. INC. is published. One employer, no account, unsubscribe in one click.
Site address
994 E. MAIN ST.
City
MONDOVI
State
WI
ZIP
54755
Mailing
PO BOX 20, MONDOVI, WI 54755
Inspection type
Accident-driven (A)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Data loaded
NAICS code
000000
SIC code (legacy)
7699
Employees
35
Ownership type
A

1 citation on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 1 exposed
Issued
Dec 26, 2000
Abate by
Dec 29, 2000
Penalty
Initial $3,500 · Current $3,500
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to the hazard of being burned:
(a)On or about June 30, 2000; an employee lit the contents of an old
diesel barrel;
used by the company to incinerate waste such as but not limited to paper,
cardboard, and shipping crates; with a match which resulted in an
explosion and
fire.
Among other methods, one feasible and acceptable abatement method to
correct this hazard is
to:
Follow the National Fire Protection Association Codes and Standards:
(1)NFPA 82 - 1999, 2-2.2.2 which states "Explosion relief shall be
provided.  The
area of explosion relief shall be not less than 1 ft2 (0.09 m2) of relief
area for
every 100 ft3 (3 m3) of primary combustion chamber volume.  Where the
exhaust
chimney will not serve the above purpose, a door or panel shall be
provided and
arranged to allow the door or panel to return to a closed position
promptly after
pressure has been released.";
(2)NFPA 82 - 1999, 2-2.2.3(c) which states "The combustion chamber, inner
walls,
roofs, bridges, walls, and curtain walls shall be constructed so as to
withstand the
combustion temperatures involved and shall maintain their integrity under
all
operating conditions."; and
(3)NFPA 82 - 1999, 2-2.2.5 which states "Incinerators shall be designed
with
internal insulation or refractory or shall be otherwise protected by
location, guard
rails, or shields such that all areas or surfaces normally accessible to
personnel
shall not exceed 160F (71.1C)...Handles of operating doors shall not exceed
a 40F (4.4C) rise for metallic and a 60F (15.6C) rise for
nonmetallic."dles

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 106053788.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.