EAU CLAIRE, WI ·
OSHA Inspection: AMERICAN PHOENIX, INC.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of AMERICAN PHOENIX, INC. in 800 WISCONSIN ST., EAU CLAIRE, WI 54703 (NAICS 326299). OSHA activity number 106054182.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AMERICAN PHOENIX, INC.
- Site address
- 800 WISCONSIN ST.
- City
- EAU CLAIRE
- State
- WI
- ZIP
- 54703
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- Non-union (N)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326299
- SIC code (legacy)
- 3069
- Employees
- 107
- Ownership type
- Private (A)
- Industry flags
- Manufacturing health.
Citations
23 citations on file for this inspection.
1910.134 D03
- Issued
- Feb 28, 2003
- Abate by
- Apr 16, 2003
5(a)(1)
- Issued
- Dec 6, 2002
- Abate by
- Jan 8, 2003
- Penalty
- Initial $1,100 · Current $660 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: (a)Throughout the facility - especially in the compounding and penthouse areas; employees were exposed to the hazard of being struck by falling loads, such as sacks of bulk material suspended via electric hoists and cris-cross bag holders that are "below the hook devices". Load ratings were not marked. The company did not have electric hoists and auxiliary equipment inspected on a frequent basis (daily to monthly) and periodic basis (at least every twelve months) to determine wear, deterioration and malfunction as per ASME B30.16-1998. Among other methods, feasible and acceptable methods to correct these hazards include; but are not limited to: 1.Determine the load rating of the supporting structure, ensuring that it is at least equal to that of the hoists, or provide a structure with such a rating, as per ANSI B30.16-1.3.2. 2.Perform frequent inspections at daily to monthly intervals and periodic inspections at monthly to yearly intervals as per ANSI B30.16-2.1, 2.1.2., 2.1.3., or the owner's manual. Written, dated and signed inspection reports should be maintained at time intervals specified in ANSI B30.16- 2.1.1(b)(2). 3.Ensure that below-the-hook lifting devices ( i.e. cris cross bag supports) are designed, installed, and maintained in proper condition with trained operators. Perform frequent inspections at daily to monthly intervals and periodic inspections at monthly to yearly intervals per ANSI B30.20-1.1., 1.2., 1.3., 1.4, 1.5 and 1.6 ( Structural and Mechanical Lifting Devices). Records of periodic inspections shall be maintained, or the device marked to indicate the inspection was performed per ANSI B30.20.1.2 and 1.3(b)(2).
Recent events (2)
- · I (S) $660.00
- · Z (S) $1100.00
1910.179 J02 III
- Issued
- Dec 6, 2002
- Abate by
- Jan 3, 2003
1910.179 J03
- Issued
- Dec 6, 2002
- Abate by
- Jan 8, 2003
1910.132 D01
- Issued
- Dec 6, 2002
- Abate by
- Dec 26, 2002
- Penalty
- Initial $1,375 · Current $825 Reduced
Recent events (2)
- · I (S) $825.00
- · Z (S) $1375.00
1910.137 B02 VIII
- Issued
- Dec 6, 2002
- Abate by
- Jan 8, 2003
1910.335 A01 V
- Issued
- Dec 6, 2002
- Abate by
- Dec 12, 2002
1910.147 C05 II
- Issued
- Dec 6, 2002
- Abate by
- Jan 3, 2003
- Penalty
- Initial $1,375 · Current $825 Reduced
Recent events (2)
- · I (S) $825.00
- · Z (S) $1375.00
1910.147 C06 I
- Issued
- Dec 6, 2002
- Abate by
- Jan 17, 2003
Recent events (2)
- · I (S)
- · Z (S)
1910.147 F03 II
- Issued
- Dec 6, 2002
- Abate by
- Jan 8, 2003
1910.212 A01
- Issued
- Dec 6, 2002
- Abate by
- Jan 3, 2003
- Penalty
- Initial $1,100 · Current $660 Reduced
Recent events (2)
- · I (S) $660.00
- · Z (S) $1100.00
1910.219 C02 I
- Issued
- Dec 6, 2002
- Abate by
- Dec 6, 2002
1910.215 B09
- Issued
- Dec 6, 2002
- Abate by
- Jan 3, 2003
- Penalty
- Initial $825
Recent events (2)
- · I (O)
- · Z (S) $825.00
1910.305 B02
- Issued
- Dec 6, 2002
- Abate by
- Dec 12, 2002
- Penalty
- Initial $825 · Current $495 Reduced
Recent events (2)
- · I (S) $495.00
- · Z (S) $825.00
1910.305 D
- Issued
- Dec 6, 2002
- Abate by
- Jan 3, 2003
1910.23 C01
- Issued
- Dec 6, 2002
- Abate by
- Jan 3, 2003
1910.95 D01
- Issued
- Dec 6, 2002
- Abate by
- Feb 7, 2003
1910.95 G01
- Issued
- Dec 6, 2002
- Abate by
- Feb 7, 2003
Recent events (2)
- · I (O)
- · Z (O)
1910.146 C01
- Issued
- Dec 6, 2002
- Abate by
- Jan 8, 2003
1910.157 E03
- Issued
- Dec 6, 2002
- Abate by
- Dec 30, 2002
1910.216 F02
- Issued
- Dec 6, 2002
- Abate by
- Jan 31, 2003
Recent events (2)
- · I (O)
- · Z (O)
1910.242 B
- Issued
- Dec 6, 2002
- Abate by
- Dec 30, 2002
1910.1001 K01
- Issued
- Dec 6, 2002
- Abate by
- Dec 26, 2002
More inspections at American Phoenix, INC.
View American Phoenix, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 326299)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 106054182.