PRATTVILLE, AL —
OSHA Inspection: CONTINENTAL EAGLE CORPORATION
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of CONTINENTAL EAGLE CORPORATION in 201 GIN SHOP HILL ROAD, PRATTVILLE, AL 36067 (NAICS 000000). OSHA activity number 106102122.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CONTINENTAL EAGLE CORPORATION
- Site address
- 201 GIN SHOP HILL ROAD
- City
- PRATTVILLE
- State
- AL
- ZIP
- 36067
- Mailing
- P.O. BOX 1000, PRATTVILLE, AL 36067
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 3559
- Employees
- 385
- Ownership type
- A
Citations
14 citations on file for this inspection.
5(a)(1)
- Issued
- Dec 15, 1995
- Abate by
- Jul 16, 1996
- Penalty
- Initial $4,500 · Current $3,139 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to fall and crushing hazards: Warehouse building, small and large elevators for all floors serviced by the elevators. Passenger and freight elevator doors operated such that they (could be) opened when the elevator car was positioned on another floor, and while the elevator door was partially open, employees from a different floor could access the elevator and the elevator car would start moving. Among other methods, one feasible and acceptable abatement method to correct these hazards is to equip the doors with interlocks that would not allow the elevator doors to open unless the car is behind the doors, and with interlocks that would not allow the elevator to operate if any of the doors were open. Standards covering the safety requirements for elevators are referenced in the American National Standard Safety Code for Elevators, Dumbwaiters Escalators and Moving Walks, ANSI A17.1-1978, Section III - Hoistway Door Locking Devices, Car Door or Gate Electric Contacts, Hoistway Access Switches, and Elevator Parking Devices, Rules 111.1, 111.2 and 111.3.
Recent events (3)
- — P (S) $3139.00
- — I (S) $3139.00
- — Z (S) $4500.00
1910.22 A01
- Issued
- Dec 15, 1995
- Abate by
- Jan 17, 1996
- Penalty
- Initial $4,500 · Current $3,139 Reduced
Recent events (2)
- — I (S) $3139.00
- — Z (S) $4500.00
1910.22 D01
- Issued
- Dec 15, 1995
- Abate by
- Jan 17, 1996
Recent events (2)
- — I (S)
- — Z (S)
1910.23 A08
- Issued
- Dec 15, 1995
- Abate by
- Jan 17, 1996
Recent events (2)
- — I (S)
- — Z (S)
1910.178 P01
- Issued
- Dec 15, 1995
- Abate by
- Dec 19, 1995
- Penalty
- Initial $3,150 · Current $2,198 Reduced
Recent events (2)
- — I (S) $2198.00
- — Z (S) $3150.00
1910.212 A01
- Issued
- Dec 15, 1995
- Abate by
- Aug 16, 1996
- Penalty
- Initial $1,800 · Current $1,256 Reduced
Recent events (3)
- — P (S) $1256.00
- — I (S) $1256.00
- — Z (S) $1800.00
1910.217 B02
- Issued
- Dec 15, 1995
- Abate by
- Dec 23, 1995
- Penalty
- Initial $1,800 · Current $1,256 Reduced
Recent events (2)
- — I (S) $1256.00
- — Z (S) $1800.00
1910.217 B03 I
- Issued
- Dec 15, 1995
- Abate by
- Dec 23, 1995
- Penalty
- Initial $1,800 · Current $1,800
Recent events (2)
- — I (S) $1800.00
- — Z (S) $1800.00
1910.217 C01 I
- Issued
- Dec 15, 1995
- Abate by
- Dec 23, 1995
- Penalty
- Initial $1,800 · Current $1,256 Reduced
Recent events (2)
- — I (S) $1256.00
- — Z (S) $1800.00
1910.217 C02 IA
- Issued
- Dec 15, 1995
- Abate by
- Dec 23, 1995
Recent events (2)
- — I (S)
- — Z (S)
1910.217 E01 I
- Issued
- Dec 15, 1995
- Abate by
- Dec 23, 1995
- Penalty
- Initial $1,800 · Current $1,256 Reduced
Recent events (2)
- — I (S) $1256.00
- — Z (S) $1800.00
1910.132 D02
- Issued
- Dec 15, 1995
- Abate by
- Dec 23, 1995
1910.147 C04 I
- Issued
- Dec 15, 1995
- Abate by
- Mar 1, 1996
Recent events (2)
- — I (O)
- — Z (O)
1910.147 C06 I
- Issued
- Dec 15, 1995
- Abate by
- Mar 1, 1996
Recent events (2)
- — I (O)
- — Z (O)
More inspections at Continental Eagle Corporation
View Continental Eagle Corporation's full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in AL
Source