OSHA Inspection: BUNGY JUMP INTL., INC. DBA: GUAM BUNGY JUMP CENTER

Accident-driven inspection · Safety discipline

On , OSHA opened an accident-driven safety inspection of BUNGY JUMP INTL., INC. DBA: GUAM BUNGY JUMP CENTER in TALOFOFO RIVER, TALOFOFO, GU 96930 (NAICS 000000). OSHA activity number 106189772.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Bungy Jump Intl., INC. DBA: Guam Bungy Jump Center for free Get an email when a new federal OSHA severe-injury report for Bungy Jump Intl., INC. DBA: Guam Bungy Jump Center is published. One employer, no account, unsubscribe in one click.
Site address
TALOFOFO RIVER
City
TALOFOFO
State
GU
ZIP
96930
Mailing
359 "C" MARINE DRIVE, SUITE NO. 4, TAMUNING, GU 96911
Inspection type
Accident-driven (A)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (N)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
000000
SIC code (legacy)
7999
Employees
7
Ownership type
Private (A)

4 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 1 exposed
Issued
Mar 24, 1995
Abate by
Apr 5, 1995
Penalty
Initial $1,500 · Current $1,500
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that periodic
inspections of a hammerhead tower crane's hoist rope were not performed
where:  the inspection
covered the entire length of the rope, any deterioration resulting in
appreciable loss of original
strength was noted, and a determination made as to whether further use of
the rope would
constitute a hazard:
a)Bungy Jump Site - Inspections of the hoist rope were not performed on a
Raimondi hammerhead tower crane, model number ER 135, serial number TK
5515-8, where:  the inspection covered the entire length of the rope, any
deterioration resulting in appreciable loss of original strength was
noted, and a
determination made as to whether further use of the rope would constitute a
hazard, exposing employees riding on the personnel platform to assist
bungy jump
customers, to the hazard of falling from an elevation of about 190 feet to
the
river
below.
Among other methods, one feasible and acceptable abatement method to
correct
this hazard is to perform periodic inspections of a hammerhead crane's
hoist rope
where:  the inspection covers the entire length of the rope, any
deterioration
resulting in appreciable loss of original strength is noted, and a
determination is
made as to whether further use of the rope would constitute a hazard as
delineated
in the American National Standards Institute/American Society of Mechanical
Engineers standard for Hammerhead Tower Cranes B 30.3, Section
3-2.4.2(b)(2)
Inspection.
Recent events (2)
  • · F (S) $1500.00
  • · Z (S) $1500.00

5(a)(1)

Willful Gravity 10 1 instance 1 exposed
Issued
Mar 24, 1995
Abate by
Apr 12, 1995
Penalty
Initial $42,000 · Current $42,000
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees
in that employees
were exposed to a hammerhead tower crane that was not provided with a
braking means with
holding power in both directions to prevent movement of the rotating upper
structure during
operation, and not capable of being set in the holding position and
remaining so without further
action on the part of the operator:
a)Bungy Jump Site - A braking means with holding power in both directions
to
prevent movement of the rotating upper structure during operation, and
capable
of being set in the holding position and remaining so without further
action on the
part of the operator was not provided to prevent movement of rotating upper
structure (Jib) of the Raimondi hammerhead tower crane, model number ER
135,
serial number TK 5515-8, exposing employees, working next to the personnel
platform being moved and lifted by the crane, to the hazard of being
struck by
the platform.
Among other methods, one feasible and acceptable abatement method to
correct
this hazard is to provide a braking means with holding power in both
directions
to prevent movement of the rotating upper structure during operation, and
capable
of being set in the holding position and remaining so without further
action on the
part of the operator as delineated in the American National Standards
Institute/American Society of Mechanical Engineers standard for Hammerhead
Tower Cranes B 30.3, Section 3-1.6.2 Slewing Brakes.
Recent events (2)
  • · F (W) $42000.00
  • · Z (W) $42000.00

5(a)(1)

Willful Gravity 10 1 instance 7 exposed
Issued
Mar 24, 1995
Abate by
Apr 12, 1995
Penalty
Initial $42,000 · Current $42,000
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to a hammerhead tower crane that did not have warning or
limiting devices
installed to prevent two blocking, the condition when the lower hook
assembly comes in contact
with the upper hook assembly or trolley:
a)Bungy Jump Site - Warning or limiting devices to prevent two blocking
were not
installed on the Raimondi hammerhead tower crane, model number ER 135,
serial
number TK 5515-8, exposing employees riding on the personnel platform to
assist
bungy jump customers, to the hazard of falling from an elevation of about
190
feet to the river below.
Among other methods, one feasible and acceptable abatement method to
correct
this hazard is to install warning or limiting devices to prevent two
blocking as
delineated in the American National Standards Institute/American Society of
Mechanical Engineers standard for Hammerhead Tower Cranes B 30.3, Section
3-3.2.2(a)(8) Personnel Lifting.
Recent events (2)
  • · F (W) $42000.00
  • · Z (W) $42000.00

1910.27 D02

Willful Gravity 10 1 instance 7 exposed
Issued
Mar 24, 1995
Abate by
Apr 5, 1995
Penalty
Initial $42,000 · Current $42,000
Recent events (2)
  • · F (W) $42000.00
  • · Z (W) $42000.00

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 106189772.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.