Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: WACKENHUT

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of WACKENHUT in 1000 JEEP PARKWAY, TOLEDO, OH 43657 (NAICS 000000). OSHA activity number 106274285.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Wackenhut — free Get an email when a new federal OSHA severe-injury report for Wackenhut is published. One employer, no account, unsubscribe in one click.
Establishment
WACKENHUT
Site address
1000 JEEP PARKWAY
City
TOLEDO
State
OH
ZIP
43657
Mailing
4428 SECOR RD. SUITE C, TOLEDO, OH 43623
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Y
Opened
Closing conference
Case closed
Data loaded
NAICS code
000000
SIC code (legacy)
3711
Employees
6200
Ownership type
A

2 citations on file for this inspection.

5(a)(1)

Serious Gravity 07 20 instances 9 exposed
Issued
Jul 5, 1989
Abate by
Jul 21, 1989
Penalty
Initial $490 · Current $490
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
%%
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
The hazard of a robotic welding machine being activated while an
employee is in the guarded envelop enclosure and causing a crushing
injury or death.
Among other methods, one feasible and acceptable method to correct this
hazard would be to enforce the immediate use of an individual key lock-
out for each machinery repairman to be installed at the control panel
located outside of the enclosure guard fencing. Ref. ANSI Z244.1-1982
Section 4 and 5, American National Standard of Minimum Safety
Requirements for Lock-out/Tagout of Energy Sources for Personnel
Protection.
Essential elements of the lockout procedure would be:
1) Open and lock out the main power disconnect for the machine and bleed
off any residual energy.
2) Provide each potentially exposede employee working in the area with
separate lock and key to be placed on the lockout means.
3) Establish a written lockout policy, including procedures to be
followed and training for all affected employees, both maintenance
and operational crews.
4) Periodically evaluate the program and strictly enforce all of its
provisions.

1910.132 A

Serious Gravity 07 1 instance 6 exposed
Issued
Jul 5, 1989
Abate by
Aug 7, 1989
Penalty
Initial $490 · Current $490

View Wackenhut's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 106274285.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.