Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,892Inspections Most recent open 2026-09-03 Last loaded 2026-09-07

OSHA Inspection: COSTELLO FRAMING COMPANY

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of COSTELLO FRAMING COMPANY in 3009 U.S. 19 NORTH, CLEARWATER, FL 34621 (NAICS 000000). OSHA activity number 106319346.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Costello Framing Company for free Get an email when a new federal OSHA severe-injury report for Costello Framing Company is published. One employer, no account, unsubscribe in one click.
Site address
3009 U.S. 19 NORTH
City
CLEARWATER
State
FL
ZIP
34621
Mailing
P.O. BOX 1692, PALM HARBOR, FL 33563
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Data loaded
NAICS code
000000
SIC code (legacy)
1751
Employees
5
Ownership type
Private (A)
Industry flags
Construction safety.

1 citation on file for this inspection.

5(a)(1)

Serious 1 instance 5 exposed
Issued
May 4, 1988
Abate by
May 11, 1988
Penalty
Initial $240 · Current $240
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
%%
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
a) Inadequate and insufficient bracing and inadequate nails were used in
a truss erection project; specifically, short 1 by 3's (1x3's) were
used where 8 foot long 2 by 4's (2x4's) were required, insufficient
diagonal and horizontal bracing was used and 6 penny nails were used
where 16 penny nails were required, exposing employees to the hazard
of collapsing trusses, on or about 4/20/88 at 3009 US 19 North,
Clearwater, FL.
Among other methods, one feasible and acceptable abatement method to
correct this hazard is to follow all the guidance in BWT-76 and adhere
to its rules regarding the use of 2 by 4's (2x4's) for all bracing, the
use of 16 penny double-headed nails in all cases, and the use of
sufficient diagonal and horizontal bracing.