TAMUNING, GU —
OSHA Inspection: GUAM DRY CLEANERS INC.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of GUAM DRY CLEANERS INC. in 151A HARMON INDUSTRIAL PARK, TAMUNING, GU 96911 (NAICS 812320). OSHA activity number 106355969.
Where did this inspection happen?
- Establishment
- GUAM DRY CLEANERS INC.
- Site address
- 151A HARMON INDUSTRIAL PARK
- City
- TAMUNING
- State
- GU
- ZIP
- 96911
- Mailing
- P.O. BOX 21929, BARRIGADA, GU 96921
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 812320
- SIC code (legacy)
- 7211
- Employees
- 50
- Ownership type
- A
- Industry flags
- Manufacturing health.
Citations
5 citations on file for this inspection.
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $2500.00 · Current $525.00 Reduced
General-duty citation text
Section 5 (a) (1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to injuries due to separation of metal parts under pressure on the hot water storage tanks and burns from the hot water and steam: a)Boiler Room - On or about April 25, 2008, and at times prior thereto, pressurized hot water was stored in non approved storage tanks which were not recognized by the American Society of Mechanical Engineers (ASME) VIII, Division 1 (Boiler and Pressure Vessel Code). AMONG OTHER MEHODS, ONE FEASIBLE AND ACCEPTABLE METHOD TO CORRECT THE HAZARD: Use hot water storage tanks certified in accordance with American Society of Mechanical Engineers (ASME) VIII, Division 1 (Boiler and Pressure Vessel Code) and marked in accordance with paragraph UG-116 of this document. b)Boiler Room - On or about April 25, 2008, and at times prior thereto, the hot water boiler providing hot water and steam to hot water storage tanks for plant use did not receive inspections to verify the boilers were safe to operate. AMONG OTHER MEHODS, ONE FEASIBLE AND ACCEPTABLE METHOD TO CORRECT THE HAZARD: Inspect boilers by a certified boiler inspector in accordance with the National Board Inspection Code for Boilers and Pressure Vessels Part 2, Section 1 Paragraph 1.5; and Section 2, paragraph 2.2.. NOTE: Inspection frequency shall be determined in accordance with the National Board Inspection Code for Boilers and Pressure Vessels Part 2, paragraph 4.4. c)Boiler Room - On or about April 25, 2008, and at times prior thereto, the hot water storage tanks (unfired pressure vessels) did not receive inspections to verify the storage tanks were safe to store pressurized hot water and steam. AMONG OTHER MEHODS, ONE FEASIBLE AND ACCEPTABLE METHOD TO CORRECT THE HAZARD: Inspect hot water storage tanks by a certified boiler inspector in accordance with the National Board Inspection Code for Boilers and Pressure Vessels Part 2, Section 1 Paragraph 1.5; and Section 2, paragraph 2.3.. d)Boiler Room - On or about April 25, 2008, and at times prior thereto, the hot water storage tanks and boiler piping did not receive inspections to verify the piping was safe for the pressurized hot water and steam. The employer utilized non-ferrous (galvanized) piping connected to a ferrous metal hot water storage tank in a corrosive environment; thereby, creating accelerated galvanic corrosion. The piping connection on one storage tank was so corroded that it was held up by dimensional lumber.AMONG OTHER MEHODS, ONE FEASIBLE AND ACCEPTABLE METHOD TO CORRECT THE HAZARD: Inspect piping systems by a certified boiler inspector in accordance with the National Board Inspection Code for Boilers and Pressure Vessels Part 2, Section 1 Paragraph 1.5; and Section 2, paragraph 2.4..
Recent events (2)
- — I (S) $525.00
- — Z (S) $2500.00
1910.22 A02
- Issued
- Abate by
- Penalty
- Initial $525.00
Recent events (2)
- — I (S)
- — Z (S) $525.00
1910.178 P01
- Issued
- Abate by
- Penalty
- Initial $525.00 · Current $525.00
Recent events (2)
- — I (S) $525.00
- — Z (S) $525.00
1910.178 Q07
- Issued
- Abate by
Recent events (2)
- — I (S)
- — Z (S)
1910.303 F
- Issued
- Abate by
Recent events (2)
- — I (O)
- — Z (O)
More inspections at GUAM DRY CLEANERS INC.
TAMUNING, GU—2009-05-28 00:00:00
GUAM DRY CLEANERS INC.
TAMUNING, GU—2006-03-06 00:00:00
GUAM DRY CLEANERS INC
TAMUNING, GU—2004-06-07 00:00:00
GUAM DRY CLEANERS INC
TAMUNING, GU—2003-07-08 00:00:00
GUAM DRY CLEANERS INC
View GUAM DRY CLEANERS INC.'s full OSHA safety record →
More inspections in this industry (NAICS 812320)
ADJUNTAS, PR—2026-07-09 00:00:00
NICK A VAZQUEZ TORRES
LAUREL, MD—2026-07-08 00:00:00
BBB ENTERPRISES, INC
COLLEGE PARK, MD—2026-07-08 00:00:00
PASHAK CLEANERS LLC
BAYAMON, PR—2026-06-29 00:00:00
EDWARD MORALES MENDEZ
YAUCO, PR—2026-06-29 00:00:00
CUATRO CALLES DRY CLEANERS INC
More inspections in GU
BARRIGADA, GU—2026-01-22 00:00:00
DURI CORPORATION
TAMUNING, GU—2026-01-21 00:00:00
DLR CORPORATION
BARRIGADA, GU—2026-01-21 00:00:00
DURI CORPORATION
TAMUNING, GU—2026-01-20 00:00:00
MG CONSTRUCTION COMPANY
BARRIGADA, GU—2026-01-20 00:00:00
PFM -VERTEX-LMS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 106355969.