MERRITT ISLAND, FL ·
OSHA Inspection: AUTOCRAFT MFG.
Programmed Related inspection · Health discipline
At a glance
On , OSHA opened a programmed Related health inspection of AUTOCRAFT MFG. in 810 KEMP STREET, MERRITT ISLAND, FL 32952 (NAICS 000000). OSHA activity number 106384092.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AUTOCRAFT MFG.
- Site address
- 810 KEMP STREET
- City
- MERRITT ISLAND
- State
- FL
- ZIP
- 32952
What kind of inspection was it?
- Inspection type
- Programmed Related (I)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- Non-union (N)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 5013
- Employees
- 40
- Ownership type
- Private (A)
Citations
2 citations on file for this inspection.
5(a)(1)
- Issued
- May 16, 1991
- Abate by
- Jul 22, 1991
- Penalty
- Initial $700 · Current $700
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: the employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the potential of being struck by fragments of plastic pipe used to distribute compressed air, in the event the pipe ruptures: a) Polyvinyl chloride pipe is located throughout the building to distribute compressed air; four work stations still use the air in this company. The regulator at the manifold area indicated 80 psi. This same type configuration is also used in an adjacent business (a leasee of Autocraft Manufacturing), on or about 3/21/91. Among other methods, one feasible and acceptable method to correct this hazard is to replace the esisting plastic piping with a type that is shatter-resistant and approved for compressed air in exposed above ground locations, such as metal pipes.
1903.2 A01
- Issued
- May 16, 1991
- Abate by
- May 19, 1991
- Penalty
- Initial $350 · Current $350