ROCKLEDGE, FL —
OSHA Inspection: STARK TRUSS FLA., INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of STARK TRUSS FLA., INC. in 5050 KORBIN ROAD, ROCKLEDGE, FL 32955 (NAICS 000000). OSHA activity number 106488323.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- STARK TRUSS FLA., INC.
- Site address
- 5050 KORBIN ROAD
- City
- ROCKLEDGE
- State
- FL
- ZIP
- 32955
- Mailing
- P.O. BOX 560057, ROCKLEDGE, FL 32956
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 2439
- Employees
- 50
- Ownership type
- A
- Industry flags
- Manufacturing safety.
Citations
18 citations on file for this inspection.
5(a)(1)
- Issued
- Mar 12, 1992
- Abate by
- Apr 15, 1992
- Penalty
- Initial $1,125 · Current $565 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: (a) The hazard of being struck by plastic shards or fragments in the event of PVC piping being used to carry compressed air in the plant should shatter. The use of PVC plastic pipes for above ground trans- portatin of compressed gases in exposed plant piping (unless the pipelines are encased in shatter resistant material) is prohibited by ANSI/ASME B31.8-1986. Gas Transmission and Distribution Piping Systems Standard, and the Plastic Pipe Institute, in its Recommenda- tion B, recommends against the use of thermoplastic pipe to transport compressed air or other compressed gases in exposed plant piping. Among other methods, one feasible and acceptable abatement method to correct this hazard is to replace the PVC piping with pipes con- structed of shatter resistant materials, such as copper.
Recent events (2)
- — I (S) $565.00
- — Z (S) $1125.00
1910.106 G08
- Issued
- Mar 12, 1992
- Abate by
- Mar 17, 1992
- Penalty
- Initial $1,125 · Current $565 Reduced
Recent events (2)
- — I (S) $565.00
- — Z (S) $1125.00
1910.147 C01
- Issued
- Mar 12, 1992
- Abate by
- Apr 15, 1992
- Penalty
- Initial $1,500 · Current $750 Reduced
Recent events (2)
- — I (S) $750.00
- — Z (S) $1500.00
1910.213 G01
- Issued
- Mar 12, 1992
- Abate by
- Mar 25, 1992
- Penalty
- Initial $2,625 · Current $1,310 Reduced
Recent events (2)
- — I (S) $1310.00
- — Z (S) $2625.00
1910.213 G02
- Issued
- Mar 12, 1992
- Abate by
- Mar 20, 1992
- Penalty
- Initial $1,500 · Current $750 Reduced
Recent events (2)
- — I (S) $750.00
- — Z (S) $1500.00
1910.213 G03
- Issued
- Mar 12, 1992
- Abate by
- Mar 20, 1992
1910.213 S03
- Issued
- Mar 12, 1992
- Abate by
- Mar 20, 1992
- Penalty
- Initial $1,500 · Current $750 Reduced
Recent events (2)
- — I (S) $750.00
- — Z (S) $1500.00
1910.215 B09
- Issued
- Mar 12, 1992
- Abate by
- Mar 20, 1992
- Penalty
- Initial $1,125 · Current $565 Reduced
Recent events (2)
- — I (S) $565.00
- — Z (S) $1125.00
1910.219 D01
- Issued
- Mar 12, 1992
- Abate by
- Apr 15, 1992
- Penalty
- Initial $1,500 · Current $750 Reduced
Recent events (2)
- — I (S) $750.00
- — Z (S) $1500.00
1910.219 E01 I
- Issued
- Mar 12, 1992
- Abate by
- Apr 15, 1992
1910.219 F03
- Issued
- Mar 12, 1992
- Abate by
- Apr 15, 1992
- Penalty
- Initial $1,500 · Current $750 Reduced
Recent events (2)
- — I (S) $750.00
- — Z (S) $1500.00
1910.253 B04 III
- Issued
- Mar 12, 1992
- Abate by
- Mar 17, 1992
- Penalty
- Initial $1,125 · Current $565 Reduced
Recent events (2)
- — I (S) $565.00
- — Z (S) $1125.00
1910.1200 E01
- Issued
- Mar 12, 1992
- Abate by
- Apr 15, 1992
- Penalty
- Initial $1,125 · Current $560 Reduced
Recent events (2)
- — I (S) $560.00
- — Z (S) $1125.00
1910.1200 F05
- Issued
- Mar 12, 1992
- Abate by
- Mar 17, 1992
- Penalty
- Initial $1,125 · Current $560 Reduced
Recent events (2)
- — I (S) $560.00
- — Z (S) $1125.00
1910.1200 G01
- Issued
- Mar 12, 1992
- Abate by
- Apr 15, 1992
- Penalty
- Initial $1,125 · Current $560 Reduced
Recent events (2)
- — I (S) $560.00
- — Z (S) $1125.00
1910.1200 H
- Issued
- Mar 12, 1992
- Abate by
- Apr 15, 1992
- Penalty
- Initial $1,125 · Current $560 Reduced
Recent events (2)
- — I (S) $560.00
- — Z (S) $1125.00
1910.22 D01
- Issued
- Mar 12, 1992
- Abate by
- Mar 17, 1992
1910.23 C01
- Issued
- Mar 12, 1992
- Abate by
- Mar 17, 1992
More inspections at Stark Truss FLA., INC.
View Stark Truss FLA., INC.'s full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 106488323.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.